(5) Participating nodes
Area 1
Area 1
(1) Area and Start Word
(2) Size
(Same as (2).)
(Same as (2).)
(Same as (2).)
Area 2
(3) Area and Start Word
Area 2
(4) Size
(Same as (4).)
No. Item
Description
of
function
(1)
Area and Start Word
for Area 1
Set the area and the start data link word
to use for area 1.
(2)
Size of Area 1
Set the send size per node for area 1.
(3)
Area and Start Word
for Area 2
Set the area and the start data link word
to use for area 2.
(4)
Size of Area 2
Set the send size per node for area 2.
(5)
Nodes
Set the nodes to participate in the data
links.
(6)
Status start word
Set the first word to store data link status.
(If 0 words is set, the default area will be
used.)
Features of Equality Layout
•
The send data sizes is the same for all nodes for each area.
•
Area 1 is selected from the bit-access areas (e.g., CIO Area) and area 2 is
selected from word-access areas (e.g., DM Area).
•
Data link areas are allocated in ascending order of node addresses.
•
Data link participation can be specified for each node.
•
The same data link areas are shared by all nodes participating in the data links.
•
Common Type
(2)
(3)
(5)
(6)
(8 )
(7)
(1 )
(4 )
No. Item
Description
of
function
(1)
Area and Start Word
for Area 1
Set the area and the start data link word
to use for area 1.
(2)
Master size
Set the area 1 send size for the master
node.
(3)
Slave size
Set the area 1 send size for the slave
node.
(4)
Area and Start Word
for Area 2
Set the area and the start data link word
to use for area 2.
(5)
Master size
Set the area 2 send size for the master
node.
(6)
Slave size
Set the area 2 send size for the slave
node.
(7)
Nodes
Set the nodes to participate in the data
links.
(8)
Status start word
Set the first word to store data link status.
(If 0 words is set, the default area will be
used.)
Area 1
1
4
1
2
2
3
1
1
3
4
Area 2
1
4
1
2
2
3
1
1
3
4
Master node
Slave node
(7) Participating nodes
Area 1
(1) Area and Start Word
Area 2
(4) Area and Start Word
(2) Master size
(3) Slave size
(Same as (3).)
(Same as (3).)
(5) Master size
(6) Slave size
(Same as (6).)
(Same as (6).)
Features of Common Type 1:N Allocation
•
Data communications are 1:1 between the master node and slave nodes.
•
All slave nodes receive the data sent by the master node.
•
The master node receives all data sent by the slaves. The reception size
for the master node is thus the node send data size times the number of
slave nodes.
•
Slaves do not send or receive data with other slaves.
•
Area 1 is selected from the bit-access areas (e.g., CIO Area) and area 2 is
selected from word-access areas (e.g., DM Area).
•
Data link areas are allocated in ascending order of node addresses.
•
Data link participation can be specified for each node.
•
The same area classification can be used for both Area 1 and Area 2,
provided that the same addresses are not used (CS/CJ-series Controller
Link Units with unit Ver. 1.2 or later).
Equality Layout Settings
Common Type Settings
Summary of Contents for CX-PROGRAMMER V9
Page 1: ...Cat No W446 E1 12 CX Programmer Ver 9 CXONE AL_C V4 AL_D V4 SYSMAC OPERATION MANUAL...
Page 2: ......
Page 3: ...SYSMAC CX Programmer Ver 9 CXONE AL C V4 AL D V4 Operation Manual Revised July 2010...
Page 4: ......
Page 6: ......
Page 32: ......
Page 33: ...PART 1 CX Programmer...
Page 34: ......
Page 91: ......
Page 111: ......
Page 191: ...PART 1 CX Programmer CHAPTER 4 Reference OMRON CX Programmer _Page 108...
Page 217: ......
Page 233: ......
Page 234: ...PART 2 CX Server PLC Tools...
Page 235: ......
Page 243: ......
Page 249: ......
Page 261: ...PART 2 CX Server PLC Tools CHAPTER 2 PLC Memory Component OMRON CX Server PLC Tools_Page 18...
Page 280: ......
Page 333: ......
Page 377: ......
Page 409: ......
Page 430: ......
Page 431: ...PART 3 CX Server Runtime...
Page 432: ......
Page 476: ......
Page 482: ......
Page 498: ......
Page 524: ......
Page 534: ......
Page 535: ......
Page 536: ......