EN-10
Wiring the Inverter
Fig 4 Wiring Diagram
Voltage adjust-
ment
DC reactor to improve input
power factor (optional)
Braking Resistor
unit (optional)
Link
Magnetic
Contactor
3-phase power
380 to 480V
50/60Hz
L1
L2
L3
PE
Line
Filter
L1(R)
L2(S)
L3(T)
(+1)
(+2)
(-)
B1
B2
U/T1
V/T2
W/T3
TA1
PG-X2
(Optional)
Motor
IM/PM
TA3
TA2
P
P
PG
S1
S3
S2
S4
S5
S6
S7
BB
BB1
Multi function
Inputs
(Factory setting)
Forward run/stop
Reverse run/stop
Nominal Speed
Inspection Run
Intermediate Speed
Leveling Speed
Not used
Hardware Baseblock (note 3)
SC
+24V, 8mA
IP24V (24V)
CN5(NPN setting)
A Pulse
B Pulse
Z Pulse
Pulse Monitor Output
RS-422
(100m or less)
E(G)
MA
MB
MC
Fault contact output
250VAC, max. 1A
30VDC, max. 1A
M1
M2
M3
M5
M4
M6
Brake Command
(Factory setting)
Contactor Control
(Factory setting)
Inverter Ready
(Factory setting)
Multi-function
contact output
250VAC, max. 1A
30VDC, max. 1A
Analog input power
15V, 20mA
Master speed
reference 0 to 10V
+V
A1
AC
0 V
P
2CN
2kOhm
Analog input
(Speed reference)
2kOhm
0 to 10 V
Input option cards
Optional control power
supply input for Rescue
Operation
to terminal B1
to terminal -
Control Power
Supply Input
P0
N0
Twisted-pair
wires
Shielded
wires
Note:
1. Main circuit terminals are indicatied with double circles and
control circuit terminals are indicatied with a single circles
2. The CN5 factory setting is NPN
3. To enable the inverter both inputs, BB and BB1 must be closed. If
only one of the inputs is closed, “BB” will be displayed in the
operator panel and the inverter will not start.
Output option
cards
3CN
Summary of Contents for CIMR-L7
Page 33: ...EN 31...
Page 65: ...DE 31...
Page 97: ...ES 31...
Page 129: ...FR 31...
Page 161: ...IT 31...
Page 193: ...PT 31...
Page 195: ...RU 1 Varispeed L7 5 LC RC...
Page 198: ...RU 4 2 Omron Yaskawa Motion Control Omron Yaskawa Motion Control 3 20...
Page 199: ...RU 5 Omron Yaskawa Motion Control 1 IP00 IP20 NEMA 1 2 18 5 22 50 30 30 B 120 B 50 120...
Page 200: ...RU 6 R L1 S L2 T L3 R S T 600 PE L1 L2 L3 PE GND L1 L2 L3 GND U V W M 3...
Page 209: ...RU 15 Data Invalid 50 150 27 1 2 3 4 5 BB BB1 6 7 8 9 STOP 1 2 3 4 END 60 2...
Page 215: ...RU 21 d1 18 2 d1 18 1 H1 83 d1 18 2 H1 83 d1 17 H1 K80 d1 18 2 d1 09 1 2 FRL FRL S3 09 0...
Page 217: ...RU 23 5 DOWN DOWN n5 05 0 P 1 UP DOWN 2 n5 01 3 n5 05 0 4 5...
Page 225: ...RU 31...