W-4510 Weigh Scale Technical Reference Manual
109
Chapter 5
: Diagnostics and repair
Communication diagnostics
Bi-level input
The following table lists the bi-level inputs, terminals, and addresses. It also lists the LED
differences between the newer revision D boards and their older counterparts. All addresses
are reached through screen
529
.
Note: The Pro Pac information is for each of the four sets of terminals.
Table 17: Bi-level inputs, terminals, grounds, addresses, and LEDs
Input
#
Smart Pro
Terminal
Smart Pro
Active,
Ground
Pro Pac
Terminal
Pro Pac
Active,
Ground
Address
from
Screen 529
Older board
(Revision C
or older)
New board
(Revision D
or newer)
1
TB4
8, 9
TB2
4, 5
1102
LED 37
LED 30
2
TB5
1, 2
TB2
6, 5
1101
LED 36
LED 29
3
TB5
3, 4
TB2
7, 8
1100
LED 35
LED 28
4
TB5
5, 6
TB2
9, 8
1099
LED 34
LED 27
5
TB5
7, 9
TB2
10, 11
1098
LED 33
LED 26
6
TB5
8, 9
TB2
12, 11
1097
LED 32
LED 25
An open circuit has a no light and the address equals zero. A closed circuit has a light and an
address of one. Figure 50 is an example of a bi-level input with an open circuit.
Figure 50: Example of a bi-level input open circuit
8
9
Smart Pro
TB4
Input 1
Customer relay
Summary of Contents for W-4510
Page 9: ...Preface viii W 4510 Weigh Scale Technical Reference Manual Notes...
Page 15: ...Preface xiv W 4510 Weigh Scale Technical Reference Manual Notes...
Page 17: ...Preface xvi W 4510 Weigh Scale Technical Reference Manual Notes...
Page 29: ...Introduction 12 W 4510 Weigh Scale Technical Reference Manual Notes...
Page 125: ...Calibration 108 W 4510 Weigh Scale Technical Reference Manual Notes...
Page 145: ...Diagnostics and repair 128 W 4510 Weigh Scale Technical Reference Manual Notes...
Page 155: ...Appendix I Parameter blocks 138 W 4510 Weigh Scale Technical Reference Manual Notes...