Calibration
W-4510 Weigh Scale Technical Reference Manual
89
Procedure 26: Collect data for span Channel #1—high process
1. From
the
MAIN MENU 1 OF 2
screen, press SELECT to choose
CALIBRATE
SYSTEM
and press ENTER
2. From
018 CAL MENU 1 OF 2
screen, press SELECT to choose
CALIBRATE
GAGE
and press ENTER
3. From
008 CALIBRATE GAGE
screen, press ENTER at
SELECT CHANNEL
Note: Verify that you are using the correct product code (0-8 for Channel #1 or 9
for Channel #2)
4. From
146 CAL CHANNELS
screen, select
CAL CHANNEL #1
and press ENTER
5. From
149 CAL CHANNEL #1
screen, press SELECT to choose
MORE CAL
FUNCTIONS
and press ENTER
6. From
150 CAL CHANNEL #1
screen, press SELECT to choose
CAL HI ON
PROCESS
and press ENTER
7. From
047 CALIBRATE HI ON PROCESS
screen, press SELECT to choose either
YES
or
NO
8. From
027 CAL TIME LEFT AFTER TIMEOUT
, press ENTER when the countdown
reaches 0 seconds left
Note: Stop the conveyor at this point and collect a known length of the material.
Weigh the material and determine the lbs/ft
9. From
156 ENTER PROD VAL
screen, enter the actual value of the process and
press ENTER. Screen
156
displays again with the cursor on the
YES
line. Press
ENTER to continue
10. On
the
157 SAVE CALIBRATE RESULT IN UPPER RAM?
Screen, press ENTER
on the
YES
line to save to upper RAM or
NO
to abort the save
If you choose to save the results, the AVG. COUNT stores in memory for later use.
11.
Press SELECT to choose the
YES
and press ENTER to continue
12.
Connect the write protect jumper, JP17 and save to EEPROM
13.
Disconnect the write protect jumper, JP17.
Summary of Contents for W-4510
Page 9: ...Preface viii W 4510 Weigh Scale Technical Reference Manual Notes...
Page 15: ...Preface xiv W 4510 Weigh Scale Technical Reference Manual Notes...
Page 17: ...Preface xvi W 4510 Weigh Scale Technical Reference Manual Notes...
Page 29: ...Introduction 12 W 4510 Weigh Scale Technical Reference Manual Notes...
Page 125: ...Calibration 108 W 4510 Weigh Scale Technical Reference Manual Notes...
Page 145: ...Diagnostics and repair 128 W 4510 Weigh Scale Technical Reference Manual Notes...
Page 155: ...Appendix I Parameter blocks 138 W 4510 Weigh Scale Technical Reference Manual Notes...