Setup
W-4510 Weigh Scale Technical Reference Manual
77
Totalizer menu
004 TOTALIZER MENU
TOTALIZER #1
TOTALIZER #2
SELECT TOTAL UNITS
Figure 34: Totalizer menu screen 1of 3
030 TOTALIZER #1
0000000
LBS
RESET PRESET
HOLD
RESET/HOLD NORMAL
117 SELECT UNITS
FOR TOTALIZERS
TOTALIZER #1 UNITS
TOTALIZER #2 UNITS
Figure 35: Totalizer menu screens 2 and 3 of 3
The totalizer features are:
•
Consists of two up-counters that are associated with a particular measurement. The
totalizer can indicate tons, pounds, kilograms, or other units where summing is
necessary.
•
Takes lbs/ft from Channel #1 and multiplies that number by the belt speed from Channel
#2. It then calculates the mass rate. The totalizer gives a pulse output for each pre-
determined weight interval (i.e., 1 pulse per 100 pounds). Contact Ohmart/VEGA Field
Service to help configure this feature.
•
Begins on the CAL menu 2 of 2. Direct access is on screen 4 where two separate
totalizers are available.
•
Can be PRESET or RESET
•
Presetting involves setting in a count that produces an indication or closes a
contact when it reaches that count
•
Resetting the totalizer returns the upper counter to zero.
•
HOLD and RESET/HOLD are available options. NORMAL is necessary to revoke the
HOLD and begin count again.
Summary of Contents for W-4510
Page 9: ...Preface viii W 4510 Weigh Scale Technical Reference Manual Notes...
Page 15: ...Preface xiv W 4510 Weigh Scale Technical Reference Manual Notes...
Page 17: ...Preface xvi W 4510 Weigh Scale Technical Reference Manual Notes...
Page 29: ...Introduction 12 W 4510 Weigh Scale Technical Reference Manual Notes...
Page 125: ...Calibration 108 W 4510 Weigh Scale Technical Reference Manual Notes...
Page 145: ...Diagnostics and repair 128 W 4510 Weigh Scale Technical Reference Manual Notes...
Page 155: ...Appendix I Parameter blocks 138 W 4510 Weigh Scale Technical Reference Manual Notes...