Setup
W-4510 Weigh Scale Technical Reference Manual
79
Procedure 21: Setup totalizer #1&2 total units
1. From
004 TOTALIZER MENU
screen, press select to choose
SELECT TOTAL
UN
ITS
2. From
117 SELECT TOTAL UNITS FOR TOTALIZER
screen, select
TOTALIZER
#1 UNITS
3. From
118 TOTALS #1 UNITS
, select one of the following units of measurement:
•
LBS
•
TON
•
KGMS
And press ENTER
4. From
117 SELECT TOTAL UNITS FOR TOTALIZER
screen, select
TOTALIZER
#2 UNITS
5. From
119 TOTALS #2 UNITS
, select one of the following units of measurement:
•
LBS
•
TON
•
KGMS
And press ENTER
6.
Connect the write protect jumper JP17
7.
Save to EEPROM
8.
Disconnect the write protect jumper, JP17. This protects the information in the
EEPROM.
Summary of Contents for W-4510
Page 9: ...Preface viii W 4510 Weigh Scale Technical Reference Manual Notes...
Page 15: ...Preface xiv W 4510 Weigh Scale Technical Reference Manual Notes...
Page 17: ...Preface xvi W 4510 Weigh Scale Technical Reference Manual Notes...
Page 29: ...Introduction 12 W 4510 Weigh Scale Technical Reference Manual Notes...
Page 125: ...Calibration 108 W 4510 Weigh Scale Technical Reference Manual Notes...
Page 145: ...Diagnostics and repair 128 W 4510 Weigh Scale Technical Reference Manual Notes...
Page 155: ...Appendix I Parameter blocks 138 W 4510 Weigh Scale Technical Reference Manual Notes...