Appendix II: Auto zero feature
W-4510 Weigh Scale Technical Reference Manual
141
Procedure 40: Auto Zero feature
1.
Connect the write protect jumper JP17
2. From
the
529 APP ACCESS CODE
screen, press SELECT to enter item
2700
and
press ENTER
3.
Press SELECT to move to enter new value
1
to enable or
0
to disable and press
ENTER to continue
4. From
the
529 APP ACCESS CODE
screen, press SELECT to enter item
2701
and
press ENTER
5.
Press SELECT to move to enter new value
1
to activate sample interval or
0
to
deactivate sample interval and press ENTER to continue
6. From
the
529 APP ACCESS CODE
screen, press SELECT to enter item
2702
and
press ENTER
The number of AZs completed so far displays if the AZ is active
7. From
the
529 APP ACCESS CODE
screen, press SELECT to enter item
2702
and
press ENTER
The address of blending line belt LDC (0=running, 1=not running)
8.
Connect Jumper JP 17
9. From
100 EEPROM SERVICE
screen, choose
SELECT COPY RAM TO
EEPROM
10. Screen
102 RAM TO EEPROM
screen displays. Enter
1
and press ENTER to
initiate the transfer. If a zero displays, the transfer was successful. If a one
displays, the transfer was unsuccessful
If the transfer was unsuccessful, verify that the jumper on JP17 is in place. It is
necessary to place the jumper on JP17 to enable any uploading to the EEPROM
11.
Disconnect the write protect jumper, JP17. This protects the information in the
EEPROM.
Summary of Contents for W-4510
Page 9: ...Preface viii W 4510 Weigh Scale Technical Reference Manual Notes...
Page 15: ...Preface xiv W 4510 Weigh Scale Technical Reference Manual Notes...
Page 17: ...Preface xvi W 4510 Weigh Scale Technical Reference Manual Notes...
Page 29: ...Introduction 12 W 4510 Weigh Scale Technical Reference Manual Notes...
Page 125: ...Calibration 108 W 4510 Weigh Scale Technical Reference Manual Notes...
Page 145: ...Diagnostics and repair 128 W 4510 Weigh Scale Technical Reference Manual Notes...
Page 155: ...Appendix I Parameter blocks 138 W 4510 Weigh Scale Technical Reference Manual Notes...