Procedure 27: Calculate calibration—Channel #1
1. From
146 CAL CHANNELS
screen, select
CAL CHANNEL #1
and press ENTER
2. From
149 CAL CHANNEL #1
screen, press SELECT to choose
MORE CAL
FUNCTIONS
and press ENTER
3. From
150 CAL CHANNEL #1
screen, press SELECT to choose
MORE CAL
FUNCTIONS
and press ENTER
4. From
151 CAL CHANNEL #1
screen, press SELECT to choose
MORE CAL
FUNCTIONS
and press ENTER
5. From
152 CAL CHANNEL #1
screen, press SELECT to choose
TWO POINT
CALIBRATE
and press ENTER
6. From
155 TWO POINT CAL HAVE YOU DONE A CAL LO AND CAL HI FIRST?
screen, select
YES
and press ENTER
7. From
157 SAVE CALIBRATE RESULT IN UPPER RAM?
screen, select
YES
and
press ENTER
8.
Press PREVIOUS SCREEN until you return to
MAIN MENU
9.
Disconnect the write protect jumper, JP17. This protects the information in the
EEPROM
10.
Connect the write protect jumper, JP17 and save to EEPROM
11.
Disconnect the write protect jumper, JP17.
Summary of Contents for W-4510
Page 9: ...Preface viii W 4510 Weigh Scale Technical Reference Manual Notes...
Page 15: ...Preface xiv W 4510 Weigh Scale Technical Reference Manual Notes...
Page 17: ...Preface xvi W 4510 Weigh Scale Technical Reference Manual Notes...
Page 29: ...Introduction 12 W 4510 Weigh Scale Technical Reference Manual Notes...
Page 125: ...Calibration 108 W 4510 Weigh Scale Technical Reference Manual Notes...
Page 145: ...Diagnostics and repair 128 W 4510 Weigh Scale Technical Reference Manual Notes...
Page 155: ...Appendix I Parameter blocks 138 W 4510 Weigh Scale Technical Reference Manual Notes...