Setup
W-4510 Weigh Scale Technical Reference Manual
61
Procedure 13: Setup communication port
1. From
230 COMM PORT SETUP
screen, press SELECT to move to one of the
following baud rates:
•
9600 (default)
•
1200
•
4800
•
300
•
2400
•
19200
Press ENTER to select
2 Screen
231 COMM PORT SETUP
displays the prompt, “HOW MANY DATA
BITS?”
Select either of the following:
•
8-bits (default)
•
7-bits
Press ENTER
3. Screen
232 COMM PORT SETUP
displays the prompt, “SELECT PARITY.”
Select one of the following:
•
NONE (default)
•
ODD
•
EVEN
Press ENTER
4 Screen
233 COMM PORT SETUP
displays, “HOW MANY STOP BITS?”
Select from either of the following:
•
2-BITS
•
1-BIT (default)
Press ENTER
5.
Connect the write protect jumper JP17
6. Screen
234 COMM PORT SETUP
displays, “SAVE IN EEPROM?”
Select
YES
or
NO
and press ENTER
7.
Disconnect the write protect jumper, JP17. This protects the information in the
EEPROM.
Summary of Contents for W-4510