Appendix II: Auto zero feature
140
W-4510 Weigh Scale Technical Reference Manual
529 APP CODE ACCESS
ADR 2700
_
CURRENT VAL
NEW VAL
0
_
Figure 70: Auto zero screen
Table 33: Screen 529 Auto Zero feature
Item#
Parameter Name
Parameter description
2700
AZ ENABLE
0=AZ Disabled, 1=AZ Enabled
2701
AZ STATUS
0=AZ not currently running. 1=AZ sample interval active
2702
AZ CYCLES
If AZ is active, how many AZs done so far
2703
AZC 1 VECTOR
Address of blending line belt LDC (0=running, 1=not running)
2704
AZC 2 VECTOR
Address of dry bin belt LDC
(0=running, 1=not running)
2705
AZC 3 VECTOR
Address of undefined LDC (not used)
2706
AZ PAUSE TIME
Amount of time (in quarter seconds) to wait after dry bin LDC trips before
starting AZ counter used to determine when the pause time has elapsed
2707
AZ TIMER
Time has elapsed
2708
AZ STATE
Used internally to synchronize AZ function
2709
AZ SAMPLING
1=wait over, 2=still waiting
2710
AZ CUTOFF ENABLE
0=Disable, 1=Enable
2711
AZ CUT OFF
VECTOR
2709 for AZ-time out
Item 2701 displays whether the auto zero is enabled or not
Item 2706 is the wait state to see that all process is cleared (entered in ¼ seconds)
The auto zero feature starts a zero and if it finishes one it will start a new one.
Item 2702 displays how many times it has gone through the auto zero cycle this session. If it
gets through at lease one auto zero then it will save the average of all cycles completed.
Note: The list of auto zeros are not in chronological order. Look for the oldest entry. Only the
last 20 zeros are saved.
Summary of Contents for W-4510
Page 9: ...Preface viii W 4510 Weigh Scale Technical Reference Manual Notes...
Page 15: ...Preface xiv W 4510 Weigh Scale Technical Reference Manual Notes...
Page 17: ...Preface xvi W 4510 Weigh Scale Technical Reference Manual Notes...
Page 29: ...Introduction 12 W 4510 Weigh Scale Technical Reference Manual Notes...
Page 125: ...Calibration 108 W 4510 Weigh Scale Technical Reference Manual Notes...
Page 145: ...Diagnostics and repair 128 W 4510 Weigh Scale Technical Reference Manual Notes...
Page 155: ...Appendix I Parameter blocks 138 W 4510 Weigh Scale Technical Reference Manual Notes...