Installation
32
W-4510 Weigh Scale Technical Reference Manual
Smart Pro and Pro Pac connections
The measurement signal from pins 6 and 7 go to an Ohmart Smart Pro or Pro Pac. The
measurement signal is 0–100kHz, maximum, true digital, and satisfies RS-422 and RS-423.
See the tables below for interconnect information.
Table 8: W-4510 interconnect to Smart Pro or Pro Pac—Measure signal
From W-4510 Weigh Scale
To Smart Pro
To Pro Pac
Pin 8
TB 4-1
TB 1-4
Pin 9
TB 4-2
TB 1-5
Shield wire
TB 4-3
TB 1-12
Table 9: W-4510 interconnect to Smart Pro or Pro Pac—tachometer signal
From W-4510 Weigh Scale
To Smart Pro
To Pro Pac
Pin 13
TB 4-5
TB 1-7
Pin 14
TB 4-6
TB 1-8
Table 10: Tachometer interconnect to Smart Pro or Pro Pac—line down signal
From W-4510 Tachometer
To Smart Pro
To Pro Pac
Contact D
TB 4-8
TB 2-4
Contact E
TB 4-9
TB 2-5