Setup
W-4510 Weigh Scale Technical Reference Manual
67
Note: The W-4510 does not generally use more than one product code.
Procedure 15: Setup product code
1. From
screen
052 ENTER PASSWORD
, enter the correct password for access
level 1 and press ENTER
2.
Go to screen
527 PR CODE
Note: Screen 527 is the most important part of the computer memory. Be very
careful when entering information at this level
3.
Press HELP to go to the desired product code number
4.
Enter the new value for each item number. Use the AUTO/MAN to scroll forward
one at a time through the item numbers. Use the YES/NO to scroll backward
Warning
Do not scroll backwards past zero (0)
5.
Connect the write protect jumper JP17
6
Save to EEPROM
7.
Disconnect the write protect jumper, JP17. This protects the information in the
EEPROM.