Calibration
92
W-4510 Weigh Scale Technical Reference Manual
Step 6: Setting the absorber value
Procedure 28: Set absorber value
1.
With a moving empty belt, pull out the absorber and perform a simple data collect
to determine the value
Make a note of the absorber reading and counts
2. From
159 ENTER ABSORBER VALUES
screen, select
HIGH ABSORBER
VALUE
and press ENTER
3. From
148 HIGH ABSORBER
screen, enter the new value and press ENTER
4. Screen
148
displays, press ENTER on the
YES
line to save to upper RAM
5.
Connect the write protect jumper, JP17 and save to EEPROM
6.
Disconnect the write protect jumper, JP17.