Setup
W-4510 Weigh Scale Technical Reference Manual
53
Procedure 9: Setup analog output Channel #2
1. From
065 ANALOG OUTPUTS
screen, select
SET ANALOG OUTPUT SPAN
and
press ENTER
2. From
060 ANALOG OUTPUT SPAN
screen, select
SET OUT CHAN#2 SPAN
and press ENTER
3. From
062 TYPE OF ANALOG OUTPUT UNITS TO USE
screen, select either
•
USE STANDARD UNITS
•
USE RATE UNITS
Press ENTER
4.
If you select
USE STANDARD UNITS
perform the following steps:
•
From
064 SET ANALOG OUTPUT #2 SPAN
, select
SET LOW LIMIT
and
press ENTER
•
From
066 SET LOW LIMIT
screen, enter the new setting and press ENTER
•
Return to screen
064
by pressing PREVIOUS SCREEN
•
From screen 064, press SELECT to choose
SET HIGH LIMIT
AND press
ENTER
•
From
068 SET HIGH LIMIT
, enter the new setting and press ENTER
5.
If you select
USE RATE UNITS
perform the following steps:
•
From
064 SET ANALOG OUTPUT #2 SPAN
screen, select
SET LOW LIMIT
and press ENTER
•
From
067 SET LOW LIMIT
screen, enter the new setting and press ENTER
•
Return to screen
064
by pressing PREVIOUS SCREEN
•
From
064
screen, press SELECT to choose
SET HIGH LIMIT
and press
ENTER
•
From
069 SET HIGH LIMIT
screen, enter the new setting and press ENTER
6.
Connect the write protect jumper JP17
7.
Save to EEPROM
8.
Disconnect the write protect jumper, JP17. This protects the information in the
EEPROM.
Summary of Contents for W-4510
Page 9: ...Preface viii W 4510 Weigh Scale Technical Reference Manual Notes...
Page 15: ...Preface xiv W 4510 Weigh Scale Technical Reference Manual Notes...
Page 17: ...Preface xvi W 4510 Weigh Scale Technical Reference Manual Notes...
Page 29: ...Introduction 12 W 4510 Weigh Scale Technical Reference Manual Notes...
Page 125: ...Calibration 108 W 4510 Weigh Scale Technical Reference Manual Notes...
Page 145: ...Diagnostics and repair 128 W 4510 Weigh Scale Technical Reference Manual Notes...
Page 155: ...Appendix I Parameter blocks 138 W 4510 Weigh Scale Technical Reference Manual Notes...