Procedure 11: Setup units of measurement for Channel #1 and #2 (continued)
5. From
009 SELECT UNITS
screen, choose
SELECT CHAN#2 UNITS
and press
ENTER
6. From
087 CHANGE UNITS
screen, select one of the following units of measure:
•
SPEED
•
TEMPERATURE
•
CUSTOM
7.
For example, If you choose
SPEED
, on screen
088
you can choose from the following
measurements:
•
FT/MIN
•
MTR/MIN
•
RPM
•
Custom
If you choose
TEMPERATURE
, on screen
089
you can choose from the following
measurements:
•
DEG C
•
DEG F
•
Custom
IF you choose
CUSTOM
, from
220 SETUP CUSTOM
, you can select any of the
following functions:
•
CHANGE UNITS TEXT
, in screen
221 NEW UNITS,
type in new units and select
YES
and press ENTER to save data
•
CHANGE CONV. FACTOR
, in screen
222 NEW FACTOR,
type in new factor and
select
YES
and press ENTER to save data
•
CHANGE CONV. EXPNT
, in screen
223 CONV. EXPONENT,
type in new
exponent and select
YES
and press ENTER to save data
8.
Connect the write protect jumper JP17
9.
Save to EEPROM
10
Disconnect the write protect jumper, JP17. This protects the information in the
EEPROM.
Summary of Contents for W-4510
Page 9: ...Preface viii W 4510 Weigh Scale Technical Reference Manual Notes...
Page 15: ...Preface xiv W 4510 Weigh Scale Technical Reference Manual Notes...
Page 17: ...Preface xvi W 4510 Weigh Scale Technical Reference Manual Notes...
Page 29: ...Introduction 12 W 4510 Weigh Scale Technical Reference Manual Notes...
Page 125: ...Calibration 108 W 4510 Weigh Scale Technical Reference Manual Notes...
Page 145: ...Diagnostics and repair 128 W 4510 Weigh Scale Technical Reference Manual Notes...
Page 155: ...Appendix I Parameter blocks 138 W 4510 Weigh Scale Technical Reference Manual Notes...