Installation and Connection
page 37
rev. 00 / 04.09.2017
Fig. 17-2
Connection of flow velocity sensors, 2 pairs
18 Single external Connection for Inputs/Outputs
If there is
one
additional sensor or actuator to be connected by using the inputs/outputs
besides the sensors connected for flow velocity measurement, this can be done directly via the
connection cables for the multifunction socket. Depending on the intended purpose there are
different cable types available. All cables feature open cable ends on one side and a plug for
the multifunction socket on the other side.
F
c
For article numbers see chapter „43 Accessories“ starting at page 121.
F
c
19 Connecting the Connector Box for Inputs/Outputs
A Connector Box (Fig. 19-1 pos. 6) must be used if you wish to additionally connect more than
one sensor or actuator using the inputs/outputs besides the two maximum paths (four sensors)
used for flow velocity measurement on the NivuFlow Mobile 600 (Fig. 19-1 pos. 1).
F
c
Important Note
The Connector Box can either be fastened directly on the NivuFlow Mobile by using the
hoop guards (Fig. 19-1 pos. 2) or can be put/fastened to any other place.