Instruction manual
NivuFlow Mobile 600
page 20
rev. 00 / 04.09.2017
Note
Check the delivered instrument for accordance with your order by identifying the nameplate.
Check the nameplate for correct specification of the power supply.
F
c
The declaration of conformity is located at the end of the manual.
Nameplates
Fig. 9-4
Nameplate NivuFlow Mobile 600
10 Specifications
Measurement principle
Ultrasonic transit time (time of flight)
Power supply
- 2x rechargeable batteries 12 V / 15 Ah, lead gel
- Battery charger 100...240 V AC / 50...60 Hz / 50 VA
Enclosure
- Material: HPX high performance synthetic resin
- Weight: approx. 2.2 kg (without batteries and hoop guards)
- Protection: IP68 closed / IP67 open
Operating temperature
-20 °C…+50 °C
Storage temperature
-20 °C…+70 °C
Max. humidity
90 %, non-condensing
Display
Status LED (RGB)
Operation
Solenoid switch;
via WLAN with display and operating module (smartphone,
tablet, notebook etc.)
Number of meas. paths
2
Inputs
- 2x 0/4...20 mA (active/passive)
- 1x 0/4...20 mA (passive)
- 1x active digital input
- 1x socket for power adapter or alternative power supply
Outputs
- 1x analog output 0...10 V
- 1x potential-free digital output as SPDT / bistable
- 1x USB-A for readout of measurement values via USB stick
Storage cycle
1...60 minutes, time-cyclic or event-based
Data memory
Intern
Data transmission/
communication
- via plug-in USB stick
- via WLAN