132
BioFlo 415
y
M1360-0050
User’s Guide
2
2
4
4
A
A
P
P
P
P
E
E
N
N
D
D
I
I
X
X
D
D
:
:
C
C
O
O
R
R
R
R
O
O
S
S
I
I
O
O
N
N
R
R
E
E
S
S
I
I
S
S
T
T
A
A
N
N
C
C
E
E
T
T
A
A
B
B
L
L
E
E
S
S
O
Corrosion Rate less than 0.002” per year
P
Corrosion Rate less than 0.020” per year
Corrosion Rate from 0.020” to 0.050” per year
Corrosion Rate greater than 0.050” per year
This table shows the resistance of Type 316
350
662
20
40
60
80
100
stainless steel to the more common
300
- - -
chemicals. Many factors influence the
250
482
resistance of materials to various solutions
212
- - -
Factors which must be given consideration
175
347
for service in corrosive environments are:
150
- - -
temperature, concentration, aeration, influ-
125
257
ence of inhibiting or accelerating contamin-
100
212
ents, influence of recirculation, solids in
75
167
suspension, velocity; frequency of use, and
50
- - -
equipment design. The corrosion data is
25
77
20
40
60
80
100
reprinted from Corrosion Data Survey, 1967
C
F
Percent Concentration in Water
and 1974 Editions, published by the
National Association of Corrosion Engineers
The influence of contaminants is probably the most important from a commercial standpoint. Corrosive solutions are seldom
found that will be free to all contaminates. However, the majority of these contaminants have no influence on corrosion, but
the ones that do generally affect the conditions greatly.
When reviewing these corrosion tables, it is good to keep the following in mind:
Stainless Type 316 is resistant to chemicals.
FOOTNOTES
Footnotes for Corrosives:
Footnotes for Data Squares:
1 Poison
20 Agitated
2
Toxic
21
7 pH
3
Explosive
22
< 7 pH
4
Flammable
23
> 7 pH
5
Ingestion poison
24 No HCI, H
2
SO
4
, HaC1
6
Inhalant poison
34
No stress
7 Attacks
skin
36 300
psi
8 Irritant
37 Stress
relieved
9
Vapor harmful
45
< 60 psi
10
Ignites Organics
51
> 2.25% Mo
11 Fuming
liquid
72 over
400ºC
12 Hygroscopic
79 300
psi
13
Liberates HCL in water
80
No SO
3
14 Narcotic
15 Volatile
16
Hazardous under pressure
17 Ignites
combustibles
24 Exothermic
with
water
Summary of Contents for BioFlo 415
Page 12: ......
Page 129: ...117 New Brunswick Scientific User s Guide Figure 65a Controller Schematics left side ...
Page 130: ...118 BioFlo 415 y M1360 0050 User s Guide Figure 65a Controller Schematics right side ...
Page 145: ...133 New Brunswick Scientific User s Guide ...
Page 146: ...134 BioFlo 415 y M1360 0050 User s Guide ...
Page 147: ...135 New Brunswick Scientific User s Guide ...
Page 148: ...136 BioFlo 415 y M1360 0050 User s Guide ...
Page 149: ...137 New Brunswick Scientific User s Guide ...
Page 150: ...138 BioFlo 415 y M1360 0050 User s Guide ...
Page 151: ...139 New Brunswick Scientific User s Guide ...
Page 152: ...140 BioFlo 415 y M1360 0050 User s Guide ...
Page 153: ...141 New Brunswick Scientific User s Guide ...
Page 154: ...142 BioFlo 415 y M1360 0050 User s Guide ...
Page 155: ...143 New Brunswick Scientific User s Guide ...
Page 156: ...144 BioFlo 415 y M1360 0050 User s Guide ...
Page 157: ...145 New Brunswick Scientific User s Guide ...