APPX
Appendix 13 How to Use CPU Module Logging Configuration Tool
951
A
• Output content for each data
<File information row>
File-related information is displayed.
Ex.
The total size of the file information row can be obtained by the following equation: (when comment is output)
14(file type) + 12(model information_file version) + 2(data type information row number) + 2(data name row number) +
2(device comment row number) + 2(data start row number) + 2(comment row number) + 10(the number of tabs) + 4(CR + LF)
= 50 bytes
<Comment row>
Comments are displayed.
*3 Double quotation marks (" "), commas (,), and semicolons (;) cannot be used.
Ex.
The total size of the comment row can be obtained by the following equation:
Character size of the specified comment (depending on the specified character string) + 4(CR + LF)
Item
Description
Size
File type
[LOGGING] is output.
14 bytes
Model information_file version
When the version of CPU Module Logging Configuration Tool is "1.82L" or later and local
devices or labels are specified, "RCPU_2" is displayed in the file version, which shows the
model information.
When the version of CPU Module Logging Configuration Tool is "1.76E" or earlier, or the
version is "1.82L" or later and only global devices are specified, "RCPU_1" is displayed in the
file version, which shows the model information.
12 bytes
No. for data type information row
Numerical value indicating the position of the data type information row from the top of the file
is placed.
2 bytes
No. for data name row
Numerical value indicating the position of the data name row from the top of the file is placed.
2 bytes
No. for device comment row
Numerical value indicating the position of the device comment row from the top of the file is
placed.
2 bytes
No. for data start row
Numerical value indicating the starting position of the data row from the top of the file is
placed.
2 bytes
No. for comment row
Numerical value indicating the position of the comment row from the top of the file is placed.
When the comment row is not output, this field is blank.
0 to 2 bytes
No. for program name row
Numerical value indicating the position of the program name row from the top of the file is
placed.
2 bytes
Item
Description
Size
Comment
Comment specified in CPU Module Logging Configuration Tool is output (the comment can
contain up to 256 characters.
When no comment is set, a blank row is output).
0 to 512 bytes
Summary of Contents for MELSEC iQ-R-R00CPU
Page 2: ......
Page 151: ...9 MONITOR FUNCTION 9 1 Real Time Monitor Function 149 9 MEMO ...
Page 323: ...18 SEQUENCE SCAN SYNCHRONIZATION SAMPLING FUNCTION 321 18 MEMO ...
Page 330: ...328 20 ROUTING SETTING 20 3 Precautions MEMO ...
Page 423: ...26 BASIC CONCEPT 26 8 State Transition of the Redundant System 421 26 MEMO ...
Page 1014: ...1012 APPX Appendix 15 Added and Enhanced Functions MEMO ...
Page 1027: ......