Appendix 13 How to Use CPU Module Logging Configuration Tool
Displayed items
*1 Data output format can be created by combining the following formats.
Year: YYYY for four-digit expression; YY for two-digit expression
Month: MM
Day: DD
Hour: hh
Minute: mm
Second: ss
Millisecond: ms (three-digit expression), or s, ss, sss, ssss, sssss, ssssss, or sssssss (second unit after the decimal point, maximum of
seven digits)
Example: YY/MM/DD hh:mm:ss.sss
10/10/13 09:44:35.241
*2 When either of "Year", "Month", "Day", "Hour", "Minute", or "Second" is omitted, if opening the data logging file by GX LogViewer, the
index expression is used rather than the time expression.
GX LogViewer Version 1 Operating Manual
*3 The target comment number refers to the numbers, which correspond to the comment numbers in the [View]
[Multiple Comment
Display Setting] of the Engineering Tool.
*4 When the following user action is detected, character entry will be disabled.
Entering a character which cannot be handled with the OS language character code.
Entering a character whose language code is different from the one for characters already input in the same data logging setting.
*5 The comment number of the device comments for each program is the same as that of the device comments. The device comments for
each program are output only when a local device is specified. When a global device is specified, the comments in the device comment
file specified for the target file name are output.
*6 When "Output each program device comment" is selected and a device comment for each program that corresponds to the program
name does not exist, the comments in the device comment file specified for the target file name are output.
Item
Description
Setting range
Default
Date
Output date
Add a time stamp to data for the data logging.
The date/time format to be output can be
specified by clicking the [Set Date Line Format]
button.
Checked
Trigger information
Output trigger information
Add a mark to data items that are associated
with a trigger occurrence for the data logging. A
character string to be added to the data where a
trigger has occurred can be specified by clicking
the [Set String for Trigger] button
256 characters or less
Index
Output index
Output the index number used for checking the
logging continuity.
Data sampling interval
Output data sampling interval
Output the data collection interval.
Execution program
name or execution
program No.
Output execution program name
or program No.
Output the execution program name and
execution program number used for the data
collection.
Execution step No.
Output execution step No.
Output the step No. used for the data collection.
Device comment output
Output device comment
If the collection data was specified with the
device, the device comment is output in addition
to the device.
Not checked
Target memory
Select the storage memory for the comment file
used when the comment is displayed.
• Memory card (SD)
• Data memory
Target comment file name
Set the comment file name used when the
comment is displayed.
60 characters or less
Target comment number
Specify the comment number to be displayed.
1 to 16
Output each program device
comment
Output device comments for each program
when a local device is specified as the
collection data.
Not checked
Target memory (each program
device comment)
Specify the memory in which device comment
files for each program are stored.
• Memory card (SD)
• Data memory
Comment
Output comments
Output the comment at the top of the file.
Checked
Comment
Input the comment in this box.
256 characters or less
(No line feed can be
used.)
LOG (setting No.)
Summary of Contents for MELSEC iQ-R-R00CPU
Page 2: ......
Page 151: ...9 MONITOR FUNCTION 9 1 Real Time Monitor Function 149 9 MEMO ...
Page 323: ...18 SEQUENCE SCAN SYNCHRONIZATION SAMPLING FUNCTION 321 18 MEMO ...
Page 330: ...328 20 ROUTING SETTING 20 3 Precautions MEMO ...
Page 423: ...26 BASIC CONCEPT 26 8 State Transition of the Redundant System 421 26 MEMO ...
Page 1014: ...1012 APPX Appendix 15 Added and Enhanced Functions MEMO ...
Page 1027: ......