834
APPX
Appendix 5 List of Special Register Areas
Diagnostic information
The following is the list of special register areas relating to the diagnostic information.
No.
Name
Data stored
Details
Set by
(setting
timing)
CPU
SD0
Latest self
diagnostics error
code
Latest self
diagnostics error
code
Error codes are stored in a hexadecimal value when the diagnostics detects
an error.
S (Error)
ALL
SD1
Latest self-
diagnostics error
time
Latest self-
diagnostics error
time
The year value (four digits) of the date/time when SD0 data was updated is
stored as a BIN code.
S (Error)
ALL
SD2
The month value of the date/time when SD0 data was updated is stored as a
BIN code.
ALL
SD3
The day value of the date/time when SD0 data was updated is stored as a
BIN code.
ALL
SD4
The hour value of the date/time when SD0 data was updated is stored as a
BIN code.
ALL
SD5
The minute value of the date/time when SD0 data was updated is stored as a
BIN code.
ALL
SD6
The second value of the date/time when SD0 data was updated is stored as
a BIN code.
ALL
SD7
The day of the week value of the date/time when SD0 data was updated is
stored as a BIN code. (0: Sun, 1: Mon, 2: Tue, 3: Wed, 4: Thu, 5: Fri, 6: Sat)
ALL
SD10
Self-diagnostic
error number
Self-diagnostic
error number 1
The maximum of 16 types of error codes are stored into SD10 onwards when
the diagnostics detects an error (The same error code as one already stored
in SD10 onwards is not stored). The 17th error code onwards are not stored.
Also error codes are not stored when 16 types of error codes have already
been stored into SD10 to SD25.
S (Error)
ALL
SD11
Self-diagnostic
error number 2
ALL
SD12
Self-diagnostic
error number 3
ALL
SD13
Self-diagnostic
error number 4
ALL
SD14
Self-diagnostic
error number 5
ALL
SD15
Self-diagnostic
error number 6
ALL
SD16
Self-diagnostic
error number 7
ALL
SD17
Self-diagnostic
error number 8
ALL
SD18
Self-diagnostic
error number 9
ALL
SD19
Self-diagnostic
error number 10
ALL
SD20
Self-diagnostic
error number 11
ALL
SD21
Self-diagnostic
error number 12
ALL
SD22
Self-diagnostic
error number 13
ALL
SD23
Self-diagnostic
error number 14
ALL
SD24
Self-diagnostic
error number 15
ALL
SD25
Self-diagnostic
error number 16
ALL
SD49
Error detection
invalidation
setting
Error detection
invalidation
setting
Specify a function for which detection of continuation errors is invalidated.
(On: Invalidate (do not detect an error), Off: Do not invalidate (detect an
error))
b0: Built-in Ethernet port communication error
U
Rn
RnP
b0
Summary of Contents for MELSEC iQ-R-R00CPU
Page 2: ......
Page 151: ...9 MONITOR FUNCTION 9 1 Real Time Monitor Function 149 9 MEMO ...
Page 323: ...18 SEQUENCE SCAN SYNCHRONIZATION SAMPLING FUNCTION 321 18 MEMO ...
Page 330: ...328 20 ROUTING SETTING 20 3 Precautions MEMO ...
Page 423: ...26 BASIC CONCEPT 26 8 State Transition of the Redundant System 421 26 MEMO ...
Page 1014: ...1012 APPX Appendix 15 Added and Enhanced Functions MEMO ...
Page 1027: ......