10 TEST FUNCTION
10.2 Device test with execution conditions
159
10
Data that can be set
The following tables list the data that can be set for the device test with execution conditions.
■
Devices that can be set
*1 For bit devices, digit specification is allowed for K1 to K8 only.
*2 For word devices, bit specification is allowed.
*3 A local device, indirectly-specified device, or index-modified device can also be specified. However, a device modified with a local index
register cannot be specified.
■
Labels that can be set
*1 Only labels that exist in the read project can be specified.
*2 Labels of a program block can be specified.
*3 Digit-specified labels cannot be specified.
*4 Bit specification is allowed.
*5 Specify the array element.
*6 Specify the structure member.
Type
Device
Bit device
X, DX, Y, DY, M, L, F, SM, V, B, SB, T (contact), ST (contact), C (contact), LT (contact), LST (contact), LC (contact), FX, FY, Jn\X,
Jn\Y, Jn\SB, Jn\B
Word device
T (current value), ST (current value), C (current value), D, SD, W, SW, RD, R, ZR, Z, FD, Un\G, Jn\W, Jn\SW, U3En\G, U3En\HG
Double-word device
LT (current value), LST (current value), LC (current value), LZ
Type
Class
Data type
Global label
• VAR_GLOBAL
• VAR_GLOBAL_RETAIN
■
Primitive data type
• Bit
• Word (signed)
• Double word (signed)
• Word (unsigned)
• Double word (unsigned)
• Single-precision real number
• Double-precision real number
• Timer type
• Retentive timer type
• Counter type
• Long timer type
• Long retentive timer type
• Long counter type
■
Array
■
Structure
Local label
• VAR
• VAR_RETAIN
Summary of Contents for MELSEC iQ-R-R00CPU
Page 2: ......
Page 151: ...9 MONITOR FUNCTION 9 1 Real Time Monitor Function 149 9 MEMO ...
Page 323: ...18 SEQUENCE SCAN SYNCHRONIZATION SAMPLING FUNCTION 321 18 MEMO ...
Page 330: ...328 20 ROUTING SETTING 20 3 Precautions MEMO ...
Page 423: ...26 BASIC CONCEPT 26 8 State Transition of the Redundant System 421 26 MEMO ...
Page 1014: ...1012 APPX Appendix 15 Added and Enhanced Functions MEMO ...
Page 1027: ......