16 MULTIPLE CPU SYSTEM FUNCTION
16.4 Data Communication Between CPU Modules
297
16
16.4
Data Communication Between CPU Modules
CPU modules within a multiple CPU system can send and transfer data to each other. The refresh communication and direct
access communication enable data writing or reading between CPU modules. The following table lists the data
communication method.
Memory to be used
CPU buffer memory is utilized for data communication between the CPU modules.
Memory configuration of CPU buffer memory
This section describes the memory configuration of CPU buffer memory.
Communication method
Application
Description
Data communication with CPU buffer
memory
This method is used when data is sent
or received at the timing of each CPU
module.
The CPU module for sending the data writes data into the CPU Buffer
memory of the host CPU module. The CPU module for receiving data reads
data from the CPU Buffer memory of the sender CPU module (other CPU
modules).
Data communication with fixed scan
communication area
This method is used when data is sent
or received through adjusting the
timing between CPU modules.
The CPU module for sending the data writes data into the fixed scan
communication area (send area) of the host CPU module. The CPU module
for receiving data reads data from the fixed scan communication area
(receive area) of the host CPU module of the send source CPU module.
Memory
Communication method
Description
Area size
CPU buffer memory
Communication through direct
access
This area is used to read/write data to
the areas of the host CPU module or
other CPU modules.
512K words fixed
Refresh area
Communication through refresh
Data communication is conducted
through refresh at END processing.
Fixed scan communication area
Communication through direct
access
This area communicates the data to
the fixed scan communication area of
the host CPU module, and is used
when the host CPU module area and
another CPU module area transfer
the data at the fixed scan
communication cycles.
It is possible to change within the
range of 0 to 24K words in total. The
send area as per unit can be set
within the range of 0 to 12K words.
(
The Refresh Area in the Fixed Scan
Communication Area
Communication through refresh
The refresh operation is conducted at
the fixed scan communication cycle.
CPU buffer memory
Refresh area
Refresh area
Fixed scan communication area
Send area of CPU No.4
Refresh area
Send area of CPU No.3
Refresh area
Send area of CPU No.2
Refresh area
Send area of CPU No.1
Summary of Contents for MELSEC iQ-R-R00CPU
Page 2: ......
Page 151: ...9 MONITOR FUNCTION 9 1 Real Time Monitor Function 149 9 MEMO ...
Page 323: ...18 SEQUENCE SCAN SYNCHRONIZATION SAMPLING FUNCTION 321 18 MEMO ...
Page 330: ...328 20 ROUTING SETTING 20 3 Precautions MEMO ...
Page 423: ...26 BASIC CONCEPT 26 8 State Transition of the Redundant System 421 26 MEMO ...
Page 1014: ...1012 APPX Appendix 15 Added and Enhanced Functions MEMO ...
Page 1027: ......