Appendix 3 Troubleshooting by Symptom
When the CPU module database access function cannot be used
When the data source name cannot be set
Check the following:
When the connection test fails
When the connection test fails at the data source setting, check the following:
When the ODBC server of the CPU module cannot be connected
When the ODBC server of the CPU module cannot be connected from the personal computer, check the following:
When the connection is disconnected
When the connection of the personal computer and the CPU module to the ODBC server is disconnected, check the
following:
Check item
Action
Check if use prohibited characters are used in "Data Source Name".
Set "Data Source Name" without using prohibited characters.
Check if the number of use prohibited characters in "Data Source Name"
exceeds the range of use.
Set "Data Source Name" with the number of characters within the range of
use.
Check item
Action
Check if the CPU module supports the CPU module database access
function.
Check that the CPU module supports the CPU module database access
function. (
Page 1008 Added and Enhanced Functions)
Check if the IP address of the CPU module set in "Server" is correct.
Set the correct IP address of the CPU module in "Server". (
Check if 61461 is set in "Port".
Set 61461 in "Port". (
Page 247 Data Source Name Setup)
Check if the absolute path of the database of the CPU module set in
"Database" is correct.
Set the correct absolute path of the database in "Database". (
Check item
Action
Check if "invalid login/password" is displayed in the error message on the
personal computer.
Check that the login name and password that are set in the module parameter
of the engineering tool match those that are input to connect to the server.
(
Page 244 Built-in database access setting)
Check if "cannot open connection to server; open init timeout" is displayed in
the error message on the personal computer.
Check that the correct data source is selected to connect to the database of
the CPU module.
Check if "Communication link failure" is displayed in the error message on the
personal computer.
The maximum number of concurrently connectable databases (number of
connections) is used (
Page 233 Database specifications)
End unused applications connected with the database of the CPU module and
connect with the database again.
Check item
Action
Check if the built-in database access timer setting in the module parameter of
the engineering tool is too short.
Set the longer time for the built-in database access timer setting. (
Summary of Contents for MELSEC iQ-R-R00CPU
Page 2: ......
Page 151: ...9 MONITOR FUNCTION 9 1 Real Time Monitor Function 149 9 MEMO ...
Page 323: ...18 SEQUENCE SCAN SYNCHRONIZATION SAMPLING FUNCTION 321 18 MEMO ...
Page 330: ...328 20 ROUTING SETTING 20 3 Precautions MEMO ...
Page 423: ...26 BASIC CONCEPT 26 8 State Transition of the Redundant System 421 26 MEMO ...
Page 1014: ...1012 APPX Appendix 15 Added and Enhanced Functions MEMO ...
Page 1027: ......