13 DATABASE FUNCTION
13.3 CPU Module Database Access (from External Device) Function
247
13
Data Source Name Setup
Set the database of the CPU module connected from the personal computer.
Window
Displayed items
*1 If they are not set, input them at login to connect to the database.
Click the [Test] button to perform a connection test of the database of the CPU module in accordance with the
setting.
Item
Description
Data Source Name
Set the identification name (any character string) for specifying the connection target database from the
application.
Input 1 to 32 characters in single-byte or double-byte alphanumeric characters. Characters except for * ! ( ) = \ ?
, [ ] can be used.
Description
Input the comment. Input none, up to 1023 single-byte alphanumeric characters, or up to 512 double-byte
characters.
Server
Set the IP address of the CPU module to be connected.
Port
Set 61461. (Default setting is 61461. Do not change the value.)
Database
Set the absolute path of the database to be connected.
For example, input the following for the database folder, my_db_vv, stored in the CPUDB folder directly under the
root directory of the SD memory card.
2:\CPUDB\my_db_vv
("2:\" indicates the root directory of the SD memory card. "vv" indicates the version of the database folder.)
Default Authorization
Login Name
Set the login user to access the database which is set.
Input the user name which is set in the module parameter. (
Page 244 Built-in database access setting)
Password
Input the password which is set in the module parameter. (
Summary of Contents for MELSEC iQ-R-R00CPU
Page 2: ......
Page 151: ...9 MONITOR FUNCTION 9 1 Real Time Monitor Function 149 9 MEMO ...
Page 323: ...18 SEQUENCE SCAN SYNCHRONIZATION SAMPLING FUNCTION 321 18 MEMO ...
Page 330: ...328 20 ROUTING SETTING 20 3 Precautions MEMO ...
Page 423: ...26 BASIC CONCEPT 26 8 State Transition of the Redundant System 421 26 MEMO ...
Page 1014: ...1012 APPX Appendix 15 Added and Enhanced Functions MEMO ...
Page 1027: ......