21 - 4
21. COMPUTER LINK CONNECTION
21.1 Connectable Model List
21.1.2 Serial communication module/Computer link module
*1
Communication cannot be performed with RS-485.
A0J2-C214-S1 cannot be used.
*2
Either CH1 or CH2 can be used for the function version A. Both CH1 and CH2 can be used together for the function version B or
later.
*3
Only CH2 can be connected.
*4
Either CH1 or CH2 can be used.
*5
The computer link module version U or later supports the A2SCPU(S1), A2SHCPU(S1), A1SHCPU, A1SJHCPU and A0J2HCPU.
*6
The module operates in the device range on AnACPU.
*7
Use the serial port of a serial communication module controlled by another CPU on the multiple CPU.
CPU series
Model name
*1
MELSEC iQ-R Series
Motion controller CPU
(MELSEC iQ-R Series)
C Controller module
*7
(MELSEC iQ-R Series)
RJ71C24, RJ71C24-R2, RJ71C24-R4
MELSEC-Q(Q mode)
Motion controller CPU(Q Series)
MELSECNET/H remote I/O station
CNC C70
Robot controller (CRnQ-700)
QJ71C24
*2
, QJ71C24-R2
*2
QJ71C24N, QJ71C24N-R2, QJ71C24N-R4
QJ71CMO
*3
, QJ71CMON
*3
MELSEC-L
LJ71C24, LJ71C24-R2
MELSEC-Q (A mode)
A1SJ71UC24-R2, A1SJ71UC24-R4, A1SJ71UC24-PRF
A1SJ71C24-R2, A1SJ71C24-R4, A1SJ71C24-PRF
MELSEC-QnA(QnACPU)
MELSEC-QnA(QnASCPU)
AJ71QC24
*4
, AJ71QC24-R2
*4
, AJ71QC24-R4
*4
AJ71QC24N
*4
, AJ71QC24N-R2
*4
, AJ71QC24N-R4
*4
A1SJ71QC24
*4
, A1SJ71QC24-R2
*4
A1SJ71QC24N
*4
, A1SJ71QC24N-R2
*4
A1SJ71QC24N1
*4
, A1SJ71QC24N1-R2
*4
AJ71UC24
*4*6
A1SJ71C24-R2
*6
, A1SJ71C24-R4
*6
, A1SJ71C24-PRF
*6
A1SJ71UC24-R2
*6
, A1SJ71UC24-R4
*6
, A1SJ71C24-PRF
*6
MELSEC-A(AnCPU)
MELSEC-A(AnSCPU)
MELSEC-A
Motion controller CPU (A Series)
AJ71UC24
*4*5
A1SJ71UC24-R2
*5
, A1SJ71UC24-R4
*5
, A1SJ71UC24-PRF
*5
A1SJ71C24-R2
*5
, A1SJ71C24-R4
*5
, A1SJ71C24-PRF
*5
A1SCPUC24-R2
*5
A2CCPUC24
*4
, A2CCPUC24-PRF
*4
Summary of Contents for GT16
Page 1: ......
Page 2: ......
Page 46: ...1 4 1 OVERVIEW 1 1 Features ...
Page 54: ...2 8 2 SYSTEM CONFIGURATION 2 2 System Equipment ...
Page 60: ...3 6 3 SPECIFICATIONS 3 4 Battery specifications ...
Page 72: ...5 8 5 UL cUL STANDARDS AND EMC DIRECTIVE 5 2 EMC Directive ...
Page 102: ...6 30 6 OPTION 6 7 Connector Conversion Box ...
Page 106: ...7 4 7 INSTALLATION 7 1 Installing Procedure ...
Page 110: ...8 4 8 COMMUNICATION CABLE 8 1 Overview of Communication Cable ...
Page 130: ...9 20 9 HANDLING OF POWER WIRING AND SWITCH 9 4 Switch Wiring ...
Page 142: ...10 12 10 UTILITY FUNCTION 10 3 Utility Display ...
Page 184: ...11 42 11 DISPLAY AND OPERATION SETTINGS GOT SET UP 11 4 Maintenance Function ...
Page 202: ...12 18 12 COMMUNICATION INTERFACE SETTING COMMUNICATION SETTING 12 3 Ethernet Setting ...
Page 226: ...13 24 13 DEBUG 13 3 Memory Data Control ...
Page 248: ...14 22 14 SELF CHECK 14 2 Batch Self Check ...
Page 350: ...15 102 15 DATA CONTROL 15 3 OS Project Information ...
Page 410: ...19 22 19 TROUBLESHOOTING 19 2 Error Message and System Alarm ...
Page 418: ...App 8 APPENDICES Appendix 3 Transportation Precautions ...
Page 422: ...REVISIONS 4 ...
Page 425: ......
Page 426: ......
Page 427: ......
Page 428: ......
Page 470: ......
Page 510: ...21 22 21 COMPUTER LINK CONNECTION 21 6 Precautions ...
Page 568: ...22 58 22 ETHERNET CONNECTION 22 5 Precautions ...
Page 584: ......
Page 626: ...25 14 25 SERVO AMPLIFIER CONNECTION 25 7 Precautions ...
Page 632: ...26 6 26 ROBOT CONTROLLER CONNECTION 26 6 Precautions ...
Page 647: ...MULTIPLE GOT CONNECTIONS 29 GOT MULTI DROP CONNECTION 29 1 ...
Page 648: ......
Page 659: ...MULTI CHANNEL FUNCTION 30 MULTI CHANNEL FUNCTION 30 1 ...
Page 660: ......
Page 675: ...FA TRANSPARENT FUNCTION 31 FA TRANSPARENT FUNCTION 31 1 ...
Page 676: ......
Page 742: ...31 66 31 FA TRANSPARENT FUNCTION 31 7 Precautions ...
Page 744: ......
Page 766: ...32 22 32 CONNECTION TO IAI ROBOT CONTROLLER 32 7 Precautions ...
Page 802: ...34 10 34 CONNECTION TO OMRON TEMPERATURE CONTROLLER 34 7 Precautions ...
Page 834: ...36 18 36 CONNECTION TO KOYO EI PLC 36 6 Device Range that Can Be Set ...
Page 858: ...38 12 38 CONNECTION TO SHARP PLC 38 6 Device Range that Can Be Set ...
Page 868: ...39 10 39 CONNECTION TO SHINKO TECHNOS INDICATING CONTROLLER 39 7 Precautions ...
Page 902: ...42 6 42 CONNECTION TO TOSHIBA MACHINE PLC 42 6 Device Range that Can Be Set ...
Page 908: ...43 6 43 CONNECTION TO PANASONIC SERVO AMPLIFIER 43 7 Precautions ...
Page 970: ...48 12 48 CONNECTION TO FUJI TEMPERATURE CONTROLLER 48 7 Precautions ...
Page 1052: ...52 26 52 CONNECTION TO AZBIL CONTROL EQUIPMENT 52 7 Precautions ...
Page 1102: ...55 14 55 CONNECTION TO GE PLC 55 7 Precautions ...
Page 1114: ...57 4 57 CONNECTION TO SICK SAFETY CONTROLLER 57 5 Device Range that Can Be Set ...
Page 1128: ...59 2 59 CONNECTION TO HIRATA CORPORATION HNC CONTROLLER ...
Page 1130: ...60 2 60 CONNECTION TO MURATEC CONTROLLER ...
Page 1132: ......
Page 1270: ...62 68 62 MICROCOMPUTER CONNECTION ETHERNET 62 8 Precautions ...
Page 1271: ...MODBUS CONNECTIONS 63 MODBUS R RTU CONNECTION 63 1 64 MODBUS R TCP CONNECTION 64 1 ...
Page 1272: ......
Page 1292: ...64 12 64 MODBUS R TCP CONNECTION 64 7 Precautions ...
Page 1293: ...CONNECTIONS TO PERIPHERAL EQUIPMENT 65 VNC R SERVER CONNECTION 65 1 ...
Page 1294: ......
Page 1298: ...65 4 65 VNC R SERVER CONNECTION 65 4 Setting in Personal Computer ...
Page 1302: ...REVISIONS 4 ...
Page 1305: ......
Page 1306: ......