![Mitsubishi Electric GT16 User Manual Download Page 799](http://html.mh-extra.com/html/mitsubishi-electric/gt16/gt16_user-manual_240978799.webp)
34. CONNECTION TO OMRON TEMPERATURE CONTROLLER
34.5 Temperature Controller Side Setting
34 - 7
28
ENERG
Y MEAS
UR
ING
UNIT
/
ELECT
RIC M
UL
TI-
MEASURING
INSTRU
M
ENT
CO
NNECT
IO
N
29
GO
T
MUL
T
I-
DRO
P
CONNECTION
30
MUL
T
I-CHA
N
N
E
L
FUNCT
ION
31
F
A
TRANS
P
ARENT
FUNCTION
32
CO
NNE
C
TI
ON T
O
IA
I
ROBOT CON
T
ROLLER
33
CONNECTION
T
O
OMRON PLC
34
CO
N
N
EC
TI
O
N
T
O
OM
RON
T
E
MPERA
TURE
C
O
NT
ROL
LE
R
35
CONNECTION T
O
KEY
ENCE PLC
34.5 Temperature Controller Side Setting
POINT
POINT
POINT
OMRON temperature controller
For details of OMRON temperature controller, refer to
the following manual.
User's Manual of the OMRON temperature
controller
34.5.1 Connecting E5AN, E5EN,
E5CN, E5GN
Set the communication data by operating the key of the
temperature controller.
*1
Adjust the settings with GOT settings.
*2
Select the communication unit No. without overlapping with
that of other units.
*3
When changing the device values of the temperature
controller from the GOT, turn ON CMWT(Communications
writing) in advance.
34.5.2 Connecting E5ZN
Set the communication data by operating the key of the
temperature controller.
*1
Adjust the settings with GOT settings.
*2
Select the communication unit No. without overlapping with
that of other units.
*3
When changing the device values of the temperature
controller from the GOT, turn ON CMWT(Communications
writing) in advance.
34.5.3 Connection to interface
converter (K3SC-10)
Communication settings
Make the communication settings by operating the DIP
switch of the temperature controller.
*1
Adjust the settings with GOT settings.
*2
Set to "Without".
Settings by DIP switch
(1) Transmission speed settings
Model name
Refer to
Temperature controller
E5AN, E5EN, E5CN, E5GN
E5ZN
Interface converter
K3SC-10
Item
Set value
Protocol
CompoWay/F (Sysway)
Transmission speed
*1
9600bps, 19200bps
Data bit
*1
8bits, 7bits
Parity bit
*1
Odd, Even, None
Stop bit
*1
1bit, 2bits
Communication unit NO.
*2
0 to 99
CMWT(Communications writing)
*3
ON
Item
Set value
Transmission speed
*1
9600bps, 38400bps
Data bit
*1
8bits, 7bits
Parity bit
*1
Odd, Even, None
Stop bit
*1
1bit, 2bits
Communication unit NO.
*2
0 to 15
CMWT(Communications writing)
*3
ON
Item
Set value
Transmission speed
*1
19200bps, 38400bps
Data bit
*1
7 bits, 8 bits
Parity bit
*1
Odd, Even, None
Stop bit
*1
1bit, 2bits
Communication Type
RS-232
RS485
Echo back
*2
With, Without
Transmission
speed (bps)
Switch No.
1
2
3
1200
ON
OFF
OFF
2400
OFF
ON
OFF
4800
ON
ON
OFF
9600
OFF
OFF
OFF
19200
ON
OFF
ON
38400
OFF
ON
ON
Terminal block
for RS-422/485
communication
Terminal block
for RS-232
communication
Front of K3SC-10 body
Inside of K3SC-10 body
(When removing the front cover)
DIP switch
ON
SW
Set these
switches.
Summary of Contents for GT16
Page 1: ......
Page 2: ......
Page 46: ...1 4 1 OVERVIEW 1 1 Features ...
Page 54: ...2 8 2 SYSTEM CONFIGURATION 2 2 System Equipment ...
Page 60: ...3 6 3 SPECIFICATIONS 3 4 Battery specifications ...
Page 72: ...5 8 5 UL cUL STANDARDS AND EMC DIRECTIVE 5 2 EMC Directive ...
Page 102: ...6 30 6 OPTION 6 7 Connector Conversion Box ...
Page 106: ...7 4 7 INSTALLATION 7 1 Installing Procedure ...
Page 110: ...8 4 8 COMMUNICATION CABLE 8 1 Overview of Communication Cable ...
Page 130: ...9 20 9 HANDLING OF POWER WIRING AND SWITCH 9 4 Switch Wiring ...
Page 142: ...10 12 10 UTILITY FUNCTION 10 3 Utility Display ...
Page 184: ...11 42 11 DISPLAY AND OPERATION SETTINGS GOT SET UP 11 4 Maintenance Function ...
Page 202: ...12 18 12 COMMUNICATION INTERFACE SETTING COMMUNICATION SETTING 12 3 Ethernet Setting ...
Page 226: ...13 24 13 DEBUG 13 3 Memory Data Control ...
Page 248: ...14 22 14 SELF CHECK 14 2 Batch Self Check ...
Page 350: ...15 102 15 DATA CONTROL 15 3 OS Project Information ...
Page 410: ...19 22 19 TROUBLESHOOTING 19 2 Error Message and System Alarm ...
Page 418: ...App 8 APPENDICES Appendix 3 Transportation Precautions ...
Page 422: ...REVISIONS 4 ...
Page 425: ......
Page 426: ......
Page 427: ......
Page 428: ......
Page 470: ......
Page 510: ...21 22 21 COMPUTER LINK CONNECTION 21 6 Precautions ...
Page 568: ...22 58 22 ETHERNET CONNECTION 22 5 Precautions ...
Page 584: ......
Page 626: ...25 14 25 SERVO AMPLIFIER CONNECTION 25 7 Precautions ...
Page 632: ...26 6 26 ROBOT CONTROLLER CONNECTION 26 6 Precautions ...
Page 647: ...MULTIPLE GOT CONNECTIONS 29 GOT MULTI DROP CONNECTION 29 1 ...
Page 648: ......
Page 659: ...MULTI CHANNEL FUNCTION 30 MULTI CHANNEL FUNCTION 30 1 ...
Page 660: ......
Page 675: ...FA TRANSPARENT FUNCTION 31 FA TRANSPARENT FUNCTION 31 1 ...
Page 676: ......
Page 742: ...31 66 31 FA TRANSPARENT FUNCTION 31 7 Precautions ...
Page 744: ......
Page 766: ...32 22 32 CONNECTION TO IAI ROBOT CONTROLLER 32 7 Precautions ...
Page 802: ...34 10 34 CONNECTION TO OMRON TEMPERATURE CONTROLLER 34 7 Precautions ...
Page 834: ...36 18 36 CONNECTION TO KOYO EI PLC 36 6 Device Range that Can Be Set ...
Page 858: ...38 12 38 CONNECTION TO SHARP PLC 38 6 Device Range that Can Be Set ...
Page 868: ...39 10 39 CONNECTION TO SHINKO TECHNOS INDICATING CONTROLLER 39 7 Precautions ...
Page 902: ...42 6 42 CONNECTION TO TOSHIBA MACHINE PLC 42 6 Device Range that Can Be Set ...
Page 908: ...43 6 43 CONNECTION TO PANASONIC SERVO AMPLIFIER 43 7 Precautions ...
Page 970: ...48 12 48 CONNECTION TO FUJI TEMPERATURE CONTROLLER 48 7 Precautions ...
Page 1052: ...52 26 52 CONNECTION TO AZBIL CONTROL EQUIPMENT 52 7 Precautions ...
Page 1102: ...55 14 55 CONNECTION TO GE PLC 55 7 Precautions ...
Page 1114: ...57 4 57 CONNECTION TO SICK SAFETY CONTROLLER 57 5 Device Range that Can Be Set ...
Page 1128: ...59 2 59 CONNECTION TO HIRATA CORPORATION HNC CONTROLLER ...
Page 1130: ...60 2 60 CONNECTION TO MURATEC CONTROLLER ...
Page 1132: ......
Page 1270: ...62 68 62 MICROCOMPUTER CONNECTION ETHERNET 62 8 Precautions ...
Page 1271: ...MODBUS CONNECTIONS 63 MODBUS R RTU CONNECTION 63 1 64 MODBUS R TCP CONNECTION 64 1 ...
Page 1272: ......
Page 1292: ...64 12 64 MODBUS R TCP CONNECTION 64 7 Precautions ...
Page 1293: ...CONNECTIONS TO PERIPHERAL EQUIPMENT 65 VNC R SERVER CONNECTION 65 1 ...
Page 1294: ......
Page 1298: ...65 4 65 VNC R SERVER CONNECTION 65 4 Setting in Personal Computer ...
Page 1302: ...REVISIONS 4 ...
Page 1305: ......
Page 1306: ......