![Mitsubishi Electric GT16 User Manual Download Page 953](http://html.mh-extra.com/html/mitsubishi-electric/gt16/gt16_user-manual_240978953.webp)
47. CONNECTION TO FUJI PLC
47.2 Serial Connection
47 - 17
44
CO
NNECTIO
N T
O
PAN
ASONIC
IND
U
STRIAL
DEV
IC
ES SUNX PLC
45
CONNECTION T
O
HIT
A
CHI IES
PL
C
46
CONNECTION T
O
HIT
A
CHI P
L
C
47
CONNE
C
T
ION T
O
FUJI
P
L
C
48
CO
NN
EC
TI
O
N T
O
FU
JI
T
E
M
P
E
R
A
T
UR
E
CO
NT
RO
LL
E
R
49
CONNECTION
T
O
Y
A
SKA
W
A
PL
C
50
C
O
NNECTION T
O
YOK
OGA
W
A
PL
C
51
CON
NECT
IO
N T
O
YO
KO
G
AW
A T
EMP
ERA
TUR
E
CON
TROLLE
R
(c) Connecting terminating resistors
Turn ON/OFF the terminating resistor using RS-
485 terminating resistor ON/OFF switch.
(d) Setting of Transmission speed, Stop bit, Data bit,
Parity bit, Initializing method
Make the settings using the character configuration
switches.
Connecting to NP1L-RS1, NP1L-RS2,
NP1L-RS3, NP1L-RS4, NP1L-RS5
(1) Communication settings
Make the communication settings using setting
switches.
*1
Set the MODE switch so that the communication port of the
general communication module to be connected to the GOT
operates as a loader.
*2
The switch is not used for connection with the GOT.
*3
Turn ON the terminating switch of the general
communication module which will be a terminal.
Station number setting
Set each station number so that no station number
overlaps.
The station number can be set without regard to the
cable connection order. There is no problem even if
station numbers are not consecutive.
(a) Direct specification
Specify the station No. of the PLC to be changed
when setting device.
Setting item
Set value
Switch No.
1
2
3
4
5
6
7
8
Transmission
speed
9600bps
ON OFF ON
19200bps
OFF ON
ON
Stop bit
1bit
ON
2bits
OFF
Data bit
7bits
ON
8bits
OFF
Parity bit
Even
ON
Odd
OFF
Done
ON
None
OFF
Initializing
method
By switch
ON
ON
8
7
6
5
4
3
2
1
ON
Switch
Item
Set value
MODE switch
MODE
1 to 3
*1
RS485 station
No. switch
Station No.
*2
RS485
terminator switch
Terminator
*3
Specification range
0 to 99
MODE switch
RS485 station
No. switch
RS485
terminator switch
GOT
Station
No.3
Station
No.0
Station
No.1
Station
No.15
Station
No.6
Examples of station number setting
Summary of Contents for GT16
Page 1: ......
Page 2: ......
Page 46: ...1 4 1 OVERVIEW 1 1 Features ...
Page 54: ...2 8 2 SYSTEM CONFIGURATION 2 2 System Equipment ...
Page 60: ...3 6 3 SPECIFICATIONS 3 4 Battery specifications ...
Page 72: ...5 8 5 UL cUL STANDARDS AND EMC DIRECTIVE 5 2 EMC Directive ...
Page 102: ...6 30 6 OPTION 6 7 Connector Conversion Box ...
Page 106: ...7 4 7 INSTALLATION 7 1 Installing Procedure ...
Page 110: ...8 4 8 COMMUNICATION CABLE 8 1 Overview of Communication Cable ...
Page 130: ...9 20 9 HANDLING OF POWER WIRING AND SWITCH 9 4 Switch Wiring ...
Page 142: ...10 12 10 UTILITY FUNCTION 10 3 Utility Display ...
Page 184: ...11 42 11 DISPLAY AND OPERATION SETTINGS GOT SET UP 11 4 Maintenance Function ...
Page 202: ...12 18 12 COMMUNICATION INTERFACE SETTING COMMUNICATION SETTING 12 3 Ethernet Setting ...
Page 226: ...13 24 13 DEBUG 13 3 Memory Data Control ...
Page 248: ...14 22 14 SELF CHECK 14 2 Batch Self Check ...
Page 350: ...15 102 15 DATA CONTROL 15 3 OS Project Information ...
Page 410: ...19 22 19 TROUBLESHOOTING 19 2 Error Message and System Alarm ...
Page 418: ...App 8 APPENDICES Appendix 3 Transportation Precautions ...
Page 422: ...REVISIONS 4 ...
Page 425: ......
Page 426: ......
Page 427: ......
Page 428: ......
Page 470: ......
Page 510: ...21 22 21 COMPUTER LINK CONNECTION 21 6 Precautions ...
Page 568: ...22 58 22 ETHERNET CONNECTION 22 5 Precautions ...
Page 584: ......
Page 626: ...25 14 25 SERVO AMPLIFIER CONNECTION 25 7 Precautions ...
Page 632: ...26 6 26 ROBOT CONTROLLER CONNECTION 26 6 Precautions ...
Page 647: ...MULTIPLE GOT CONNECTIONS 29 GOT MULTI DROP CONNECTION 29 1 ...
Page 648: ......
Page 659: ...MULTI CHANNEL FUNCTION 30 MULTI CHANNEL FUNCTION 30 1 ...
Page 660: ......
Page 675: ...FA TRANSPARENT FUNCTION 31 FA TRANSPARENT FUNCTION 31 1 ...
Page 676: ......
Page 742: ...31 66 31 FA TRANSPARENT FUNCTION 31 7 Precautions ...
Page 744: ......
Page 766: ...32 22 32 CONNECTION TO IAI ROBOT CONTROLLER 32 7 Precautions ...
Page 802: ...34 10 34 CONNECTION TO OMRON TEMPERATURE CONTROLLER 34 7 Precautions ...
Page 834: ...36 18 36 CONNECTION TO KOYO EI PLC 36 6 Device Range that Can Be Set ...
Page 858: ...38 12 38 CONNECTION TO SHARP PLC 38 6 Device Range that Can Be Set ...
Page 868: ...39 10 39 CONNECTION TO SHINKO TECHNOS INDICATING CONTROLLER 39 7 Precautions ...
Page 902: ...42 6 42 CONNECTION TO TOSHIBA MACHINE PLC 42 6 Device Range that Can Be Set ...
Page 908: ...43 6 43 CONNECTION TO PANASONIC SERVO AMPLIFIER 43 7 Precautions ...
Page 970: ...48 12 48 CONNECTION TO FUJI TEMPERATURE CONTROLLER 48 7 Precautions ...
Page 1052: ...52 26 52 CONNECTION TO AZBIL CONTROL EQUIPMENT 52 7 Precautions ...
Page 1102: ...55 14 55 CONNECTION TO GE PLC 55 7 Precautions ...
Page 1114: ...57 4 57 CONNECTION TO SICK SAFETY CONTROLLER 57 5 Device Range that Can Be Set ...
Page 1128: ...59 2 59 CONNECTION TO HIRATA CORPORATION HNC CONTROLLER ...
Page 1130: ...60 2 60 CONNECTION TO MURATEC CONTROLLER ...
Page 1132: ......
Page 1270: ...62 68 62 MICROCOMPUTER CONNECTION ETHERNET 62 8 Precautions ...
Page 1271: ...MODBUS CONNECTIONS 63 MODBUS R RTU CONNECTION 63 1 64 MODBUS R TCP CONNECTION 64 1 ...
Page 1272: ......
Page 1292: ...64 12 64 MODBUS R TCP CONNECTION 64 7 Precautions ...
Page 1293: ...CONNECTIONS TO PERIPHERAL EQUIPMENT 65 VNC R SERVER CONNECTION 65 1 ...
Page 1294: ......
Page 1298: ...65 4 65 VNC R SERVER CONNECTION 65 4 Setting in Personal Computer ...
Page 1302: ...REVISIONS 4 ...
Page 1305: ......
Page 1306: ......