32. CONNECTION TO IAI ROBOT CONTROLLER
32.5 Robot Controller Side Setting
32 - 19
28
ENERG
Y MEAS
UR
ING
UNIT
/
ELECT
RIC M
UL
TI-
MEASURING
INSTRU
M
ENT
CO
NNECT
IO
N
29
GO
T
MUL
T
I-
DRO
P
CONNECTION
30
MUL
T
I-CHA
N
N
E
L
FUNCT
ION
31
F
A
TRANS
P
ARENT
FUNCTION
32
CO
NNE
C
TI
ON T
O
IA
I
ROBOT CON
T
ROLLER
33
CONNECTION
T
O
OMRON PLC
34
CO
N
N
EC
TI
O
N
T
O
OM
RON
T
E
MPERA
TURE
C
O
NT
ROL
LE
R
35
CONNECTION T
O
KEY
ENCE PLC
32.5.2 Connecting to SSEL, ASEL,
PSEL
Parameter setting
Enter the following parameters using peripheral
software. When setting parameters, set the mode
switch of the controller to "MANU".
*1
Indicates only the transmission that can be specified on the
GOT side.
Specify the transmission speed to match the baud rate of the
GOT.
*2
Set it only when a wait time is required before the response
and transmission to the GOT request. Normally, the
communication is available using default values.
Mode switch
Set the mode switch to "AUTO" and connect the GOT
to the following teaching connector.
32.5.3 Connecting to PCON, ACON,
SCON
Axis number setting and mode select
For controllers without the following switches, set from
the setting tool (PC software).
Transmission speed setting
Set the transmission speed from the setting tool (PC
software).
*1
Indicates only the transmission speeds that can be set on
the GOT side.
Specify the transmission speed to match the transmission
speed of the GOT.
Parameter
Parameter Name
Set Value
I/O parameter 90
Usage of SIO channel 0
opened to user
2: IAI protocol B
(fixed)
I/O parameter 91
Station code of SIO channel 0
opened to user
0 to 255
I/O parameter 92
*1
Baud rate type of SIO
channel 0 opened to user
0: 9600bps
1: 19200bps
2: 38400bps
3: 57600bps
5: 115200bps
I/O parameter 93
Data length of SIO channel 0
opened to user
7bit, 8bit
I/O parameter 94
Stop bit length of SIO
channel 0 opened to user
1bit, 2bit
I/O parameter 95
Parity type of SIO channel 0
opened to user
0: None
1: Odd
2: Even
I/O parameter 97
*2
IAI-protocol minimum
response delay for SIO
channel 0 opened to user
0 to 999(ms)
Other parameter
46
Other setting bit pattern 1
bit0 to 3 = 1
(fixed)
Mode switch
Teaching
connector
Switch
Set Value
Axis number setting
rotary switch
0 to 15
Mode selector switch
• Only the monitor: AUTO
• Monitor, data change: MANU
Item
Range
SIO communication
speed
*1
9600 /19200 /38400 /57600 /115200bps
Default: 38400bps
MANU
AUTO
Mode
selector switch
Axis number setting
rotary switch
Summary of Contents for GT16
Page 1: ......
Page 2: ......
Page 46: ...1 4 1 OVERVIEW 1 1 Features ...
Page 54: ...2 8 2 SYSTEM CONFIGURATION 2 2 System Equipment ...
Page 60: ...3 6 3 SPECIFICATIONS 3 4 Battery specifications ...
Page 72: ...5 8 5 UL cUL STANDARDS AND EMC DIRECTIVE 5 2 EMC Directive ...
Page 102: ...6 30 6 OPTION 6 7 Connector Conversion Box ...
Page 106: ...7 4 7 INSTALLATION 7 1 Installing Procedure ...
Page 110: ...8 4 8 COMMUNICATION CABLE 8 1 Overview of Communication Cable ...
Page 130: ...9 20 9 HANDLING OF POWER WIRING AND SWITCH 9 4 Switch Wiring ...
Page 142: ...10 12 10 UTILITY FUNCTION 10 3 Utility Display ...
Page 184: ...11 42 11 DISPLAY AND OPERATION SETTINGS GOT SET UP 11 4 Maintenance Function ...
Page 202: ...12 18 12 COMMUNICATION INTERFACE SETTING COMMUNICATION SETTING 12 3 Ethernet Setting ...
Page 226: ...13 24 13 DEBUG 13 3 Memory Data Control ...
Page 248: ...14 22 14 SELF CHECK 14 2 Batch Self Check ...
Page 350: ...15 102 15 DATA CONTROL 15 3 OS Project Information ...
Page 410: ...19 22 19 TROUBLESHOOTING 19 2 Error Message and System Alarm ...
Page 418: ...App 8 APPENDICES Appendix 3 Transportation Precautions ...
Page 422: ...REVISIONS 4 ...
Page 425: ......
Page 426: ......
Page 427: ......
Page 428: ......
Page 470: ......
Page 510: ...21 22 21 COMPUTER LINK CONNECTION 21 6 Precautions ...
Page 568: ...22 58 22 ETHERNET CONNECTION 22 5 Precautions ...
Page 584: ......
Page 626: ...25 14 25 SERVO AMPLIFIER CONNECTION 25 7 Precautions ...
Page 632: ...26 6 26 ROBOT CONTROLLER CONNECTION 26 6 Precautions ...
Page 647: ...MULTIPLE GOT CONNECTIONS 29 GOT MULTI DROP CONNECTION 29 1 ...
Page 648: ......
Page 659: ...MULTI CHANNEL FUNCTION 30 MULTI CHANNEL FUNCTION 30 1 ...
Page 660: ......
Page 675: ...FA TRANSPARENT FUNCTION 31 FA TRANSPARENT FUNCTION 31 1 ...
Page 676: ......
Page 742: ...31 66 31 FA TRANSPARENT FUNCTION 31 7 Precautions ...
Page 744: ......
Page 766: ...32 22 32 CONNECTION TO IAI ROBOT CONTROLLER 32 7 Precautions ...
Page 802: ...34 10 34 CONNECTION TO OMRON TEMPERATURE CONTROLLER 34 7 Precautions ...
Page 834: ...36 18 36 CONNECTION TO KOYO EI PLC 36 6 Device Range that Can Be Set ...
Page 858: ...38 12 38 CONNECTION TO SHARP PLC 38 6 Device Range that Can Be Set ...
Page 868: ...39 10 39 CONNECTION TO SHINKO TECHNOS INDICATING CONTROLLER 39 7 Precautions ...
Page 902: ...42 6 42 CONNECTION TO TOSHIBA MACHINE PLC 42 6 Device Range that Can Be Set ...
Page 908: ...43 6 43 CONNECTION TO PANASONIC SERVO AMPLIFIER 43 7 Precautions ...
Page 970: ...48 12 48 CONNECTION TO FUJI TEMPERATURE CONTROLLER 48 7 Precautions ...
Page 1052: ...52 26 52 CONNECTION TO AZBIL CONTROL EQUIPMENT 52 7 Precautions ...
Page 1102: ...55 14 55 CONNECTION TO GE PLC 55 7 Precautions ...
Page 1114: ...57 4 57 CONNECTION TO SICK SAFETY CONTROLLER 57 5 Device Range that Can Be Set ...
Page 1128: ...59 2 59 CONNECTION TO HIRATA CORPORATION HNC CONTROLLER ...
Page 1130: ...60 2 60 CONNECTION TO MURATEC CONTROLLER ...
Page 1132: ......
Page 1270: ...62 68 62 MICROCOMPUTER CONNECTION ETHERNET 62 8 Precautions ...
Page 1271: ...MODBUS CONNECTIONS 63 MODBUS R RTU CONNECTION 63 1 64 MODBUS R TCP CONNECTION 64 1 ...
Page 1272: ......
Page 1292: ...64 12 64 MODBUS R TCP CONNECTION 64 7 Precautions ...
Page 1293: ...CONNECTIONS TO PERIPHERAL EQUIPMENT 65 VNC R SERVER CONNECTION 65 1 ...
Page 1294: ......
Page 1298: ...65 4 65 VNC R SERVER CONNECTION 65 4 Setting in Personal Computer ...
Page 1302: ...REVISIONS 4 ...
Page 1305: ......
Page 1306: ......