5.4.2 Console Set Up
This menu defines the operating parameters of the terminal interface as shown:
Metrodata WCM3100 "" Alarms: Major
CONSOLE SET-UP
Terminal type TTY
via Modem No
Baud rate 19200 bps
Parity None
Data bits 8
Stop bits 2
Load new config.
First CAPITAL - select item
<escape> - exit menu
5.4.2.1 Terminal Type
The terminal type setting defines the output type of the user interface. There are 3
settings:
TTY
A simple terminal interface sent line by line with scrolling screens and no
cursor control, or graphics
VT100
Enhanced display for VT100 emulation with highlighted characters, cursor
control and graphic borders
ANSI
Enhanced Vt100 mode
5.4.2.2 via Modem
The WCM supports management access via a dial up modem. When a call is connected
the terminal activates when DTR is raised by the modem, and will automatically disconnect
when DTR is negated.
Options
No
Normal Terminal operation, 3 wire connection may be used
Yes
Hardware Control based interface, full RS-232 interface needed including
DTR control signal