1.2 Safety
The WCM must not be connected to cabling which would be required by BS6701 to
equipped with over voltage protection. The following ports on the WCM are designated
SELV (Safety Extra Low Voltage) within the scope of EN41003.
Terminal Port 9 Way D-Type
LAN Port(s) RJ45 10/100/1000BaseT
SFP
These ports must only be connected to SELV ports on other equipment in accordance with
EN60950 clause 2.3.
1.3 Electro Magnetic Compatibility
To ensure EMC compliance, all signal and data cables must be shielded and use
screened connector shells. The cable screens must be terminated to the screened
connector shell and not connected to any pins of the connector. Failure to use the correct
connectors may compromise EMC compliance.
1.3.1 EN55022 Statement
The WCM is a Class A product. In a domestic environment, this product may cause radio
interference, in which case the user will be required to take adequate measures.
1.3.2 FCC Declaration
This equipment has been tested and found to comply with the limits of the Class A digital
device, pursuant to Part 15 of the FCC rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the Installation and
Operation manual, may cause harmful interference to the radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in
which case the user will be required to correct the interference at his own expense.
1.4 WEEE Directive
The WCM is covered by Directive 2002/96/EC (OJ:L37/24/2003) on Waste Electrical and
Electronic Equipment (WEEE) Units must therefore not be disposed of in standard landfill.