5.5.6.3 Node Name
The node name is the SNMP MIB-2 system SysName parameter. By default this entry is
blank. The parameter may be up to 255 characters and should be configured to reflect the
actual installation requirements.
5.5.6.4 Location
The location is the SNMP MIB-2 system SysLocation parameter. By default this entry is
blank. The parameter may be up to 255 characters and should be configured to reflect the
actual installation requirements.
5.5.6.5 Managers
To enable access to the WCM using SNMP, specific manager addresses must be
configured. Once a Manager is assigned, the WCM will respond to polls and generate
traps for that manager. The WCM supports up to 10 configured Network Management
Stations. The manager may be configured to operate as SNMP V1 or V2c
The Add Manager Menu is as below:
Metrodata WCM "" Alarms: Major
ADD MANAGER
IP address 0.0.0.0
Access rights None
receives Traps No
snmp Version SNMPv2c
Remove manager
First CAPITAL - select item
<escape> - exit menu
The IP address is the IP address of the assigned Network Management Station.