METRODATA LTD
WCM1100 / WCM3100 / WCM-Serial / LHM1000 / LVM2000 User Manual
76-02-082 Rev N
83 of 169
5.3.1.7.2.3 OAM Counters
The counters provide an indication of the OAM interactions taking place. In normal
operation, the information frames should be incrementing at a rate of 1 per second.
Metrodata WCM3100 "" Alarms: Major
OAM Statistics
--------------
Rx Tx
Unsupported Codes 0 0
Information 372 373
Unique Event 0 0
Duplicate Event 0 0
Variable Request 0 0
Variable Response 0 0
Loopback Control 0 0
Organisation Specific 4 4
<Esc> - exit, C - clear, <Enter> - refresh
5.3.1.7.2.4 OAM Events
The OAM event log maintains a list of events that occur within the OAM module for the
selected port.
Metrodata WCM3100 "" Alarms: Major
OAM Events
----------
(no events)
<Esc> - exit, C - clear, <Enter> - refresh