4.4.2 WCM3100 E3 Configuration
The WCM3100 WAN E3 port configuration menu is shown below:
Metrodata WCM3100 "" Alarms: Major
WAN
State Up
Interface E3
Timing Internal
Framing G.832
First CAPITAL - select item
<escape> - exit menu
For the E3 interface, the framing mode (G.832 or Unframed) must be configured as well as
the interface timing.
4.4.3 WCM3100 DS-3 Configuration
The WCM3100 WAN DS-3 port configuration menu is shown below:
Metrodata WCM3100 "" Alarms: Major
WAN
State Up
Interface DS3
Timing Internal
tx line Build-Out 0-225ft
Framing C-Bit
First CAPITAL - select item
<escape> - exit menu
When DS-3 mode is selected, the framing mode (C-Bit or Unframed) must be set as well
as the interface timing. Additionally, the transmitter power must be configured by setting
the line build out to support either short (<225ft) or longer cable runs.