The timeout is defined in seconds, in the range 1 to 900. The default value of 60 is usually
too short for normal use, however and a value of 600 (5 minutes is usually more suitable)
For testing, a timeout of 0 may be used which disables the timeout. This should be
avoided with real unit deployments as this will prevent sessions timing out, and may lead
to a user being locked out as the 16 TCP session limit is reached.
5.5.8 TFTP
The WCM may be upgraded in the field using TFTP to upgrade the application software, or
to save or load the configuration.
In networks where firewalls and NAT addressing is used server mode must be used
otherwise either client or sever mode may be used.
5.5.8.1 TFTP Configuration
Under the management menu, select TFTP and enter the parameters as required:
5.5.8.1.1 Client Mode
Select client mode to display the menu as below:
Metrodata WCM3100 "" Alarms: Major
TFTP
Mode Client
remote IP 192.168.0.100
Get new software <display>
Boot s/w upgrade <display>
get Config.
Put config.
put Report
First CAPITAL - select item
<escape> - exit menu
5.5.8.1.1.1 Remote IP
This defines the IP address of the TFTP server which will be used.