METRODATA LTD
WCM1100 / WCM3100 / WCM-Serial / LHM1000 / LVM2000 User Manual
76-02-082 Rev N
90 of 169
5.3.2.7.2 Notifications
The Notifications menu allows traps and alarms to be generated based on alarms or
warnings raised by the SFP diagnostic information.
The menu is shown below, with a common set up with traps/alarms enabled for the high
termperature and low receive power.
Metrodata WCM3100 "WCM3100_Left" Alarms: none
NOTIFICATIONS
1 - Temp High Alarm & Warning
2 - Temp Low None
3 - Supply High None
4 - Supply Low None
5 - Bias High None
6 - Bias Low None
7 - Tx Power High None
8 - Tx Power Low None
9 - Rx Power High None
A - Rx Power Low Alarm & Warning
B - SFP Removed None
C - OTDR Fault None
First CAPITAL - select item
<escape> - exit menu
The options for each notification is as follows:
None
Do not generate a trap or alarm for this diagnostic parameter
Alarm
Generate an alarm and trap when the Alarm threshold is
exceeded.
Alarm & Warning
Generate an alarm and trap when either the Alarm or Warning
threshold has been exceeded.