Chapter 2 - Installing and Operating
45
In a similar manner, up to two transmitters boards can be installed
in the GT7700 to connect to two slave GTXI-700 platforms for a
total of three GTXI platforms. See Figure 2-16.
Thus it is possible to have up to 36 ISA instrument slots connected
to one GT7700 with two slave GTXI-700 platforms (thirteen slots
each). If more than 36 slots are needed, contact Geotest for
additional configurations.
GT7700
Slave
GTXI-700
PCT Boards
PCR Boards
Cabling
Slave
GTXI-700
Figure 2-16: GT7700 connected to two GTXI-700s
With a stand alone GTXI-700
When the GTXI-700 is used as a stand-alone computer platform,
the GTPC-7586 module contains four board slots.
A GTXI-701-PCT transmitter board can be placed in any open slot
in the GTPC module and be connected to a second GTXI-700 slave
unit via the slave’s receiver board.