Setup Guide for the RadioRA Chronos System Bridge
99
Ensure that the Chronos
TM
System Bridge is not
in Activate Controls Mode, or the ACTIVATE
REPEATER LED or ACTIVATE CONTROLS
LED on any Repeater is
NOT ON
before pro-
ceeding. If either LED is ON, press the corre-
sponding button until it's LED turns OFF
(approximately 3 seconds).
Returning Components to Default Factory Settings
Switch Closure Interface
Returning a Switch Closure Interface to Default Factory Settings will permanently delete all current pro-
gramming information.
Do not do this unless you are sure that it is necessary.
For more information
call the
Lutron Technical Support Center.
Step 1
Begin returning to Default
Factory Settings
Step 2
Complete returning to Default
Factory Settings
All LEDs (except the Power LED) will turn
OFF indicating that the Switch Closure
Interface has been returned to Default Factory
Settings.
Press and hold the Program and Closure Type
buttons until the Switch Closure Interface
resets (all LEDs will flash).
Press and hold all three buttons until Input
LEDs 1, 4, and Flash begin to flash (approxi-
mately 3 seconds).
LEDs will flash for only 3 seconds.