Setup Guide for the RadioRA Chronos System Bridge
77
Section 6 - CCI Programming
Contact Closure Programming
Setting up the Security Contact Closure Input
The Security Contact Closure Input is a special input that can be programmed to turn lights on to Full or to Flash
lights (1 second ON, 1 second OFF) when a contact closure output is detected from a security panel. Typically,
interior lights are programmed to come on to full and exterior lights are programmed to flash, thereby drawing
attention to the home. When the system is in Security Mode, all system devices will be locked out from local
operation. When Security Mode is exited (contact closure is released) system controls resume normal operation.
Follow the procedure below to program which lights will turn on to Full and which lights will Flash.
Step 1
Go to Security Setup
Main Menu
Contact Closure Setup
Security Setup
Step 2
Assign Zones to Full
From
Security Setup
, select
Assign Zones
to Full
.
Assign Dimmers or Switches by turning the
controls ON.
Note:
To use the Copy Button Feature, refer
to pages 49-51.
Assign Zones to Full
Continue
assigned to Security Full.
Turn on devices to be
Copy Button
Switch
OR
Dimmer
Assign a GRAFIK Eye
®
/GRAFIK RA
TM
Control
Unit by selecting a
GRAFIK Eye/GRAFIKRA
scene.
If the wrong Lighting Zone Control is assigned
to Security Full, turn the Lighting Zone Control
OFF to unassign it.
Press “Continue” (# button)
to return to
Security Setup
.
• Continued on next page.