Setup Guide for the RadioRA Chronos System Bridge
34
Section 3 - Button Programming
Local Button Programming
Step 1
Begin the ALL ON/ALL OFF
button programming
Programming the ALL ON and ALL OFF Buttons
ALL ON Buttons always turn ON Dimmers (to 100%), Switches, and GRAFIK Eye
®
/GRAFIK RA
TM
Control Units
(to Scene 1). ALL OFF Buttons always turn these controls OFF. By default, all Lighting Zone Controls are
assigned to all of the ALL ON and ALL OFF Buttons. To unassign controls from the ALL ON and ALL OFF
Buttons, perform the following steps. For an overview of the Master Control programming process, refer to page
25.
Step 2
Select a button
On the Master Control to be programmed,
simultaneously press and hold the 2nd and
4th buttons in the right most column until the
upper right LED begins to flash (approximate-
ly 3 seconds).
Press the ALL ON or ALL OFF button on the
Master Control to be programmed.
Upper right LED flashes.
Tabletop Master
OR
For the ALL ON button, the LEDs in all
columns will simultaneously cycle from bottom
to top.
For the ALL OFF button, the LEDs in all
columns will simultaneously cycle from top to
bottom.
LEDs cycle UP for
ALL ON
All Lighting Zone Controls will turn on.
These programming steps only apply to Master
Controls equipped with ALL ON and ALL OFF
buttons.
Wall Master
ALL ON
ALL OFF
LEDs cycle DOWN
for ALL OFF