Starting up
- 41 -
01.21
909.2669.9-02
Adjustment of the torch-ID
Every torch of the i-LTG/i-LTW-series has an own torch-ID. This
ID is related to the stress limits of the torch. If the torch protec-
tion is activated (sub-parameter “tPr” = on) in the TIG-mode,
only a welding current according to the maximum torch limit
can be adjusted at the welding machine.
The adjustment of the torch –ID is necessary for e.g. if the
torch pc-board was changed.
Â
Select in the user specific menu code-no. C00.
Â
Adjust at the turning knob 41 the required torch-ID, ac-
cording to the torch-ID chart.
Type of torch
Torch-ID
Stress limits
DC
AC
i-LTG 900
9
125 A
80 A
i-LTG 1700
17
150 A
120 A
i-LTG 2600
26
200 A
160 A
i-LTG 2800
28
300 A
250 A
i-LTW 3000
30
320 A
220 A
i-LTW 1800
18
350 A
250 A
i-LTW 1800sc
19
400 A
320 A
i-LTW 2000
20
220 A
165 A
i-LTW 4500
45
450 A
360 A
Tab. 6:
Torch-ID
Â
For saving, press button on the right, main parameter 48.
9
The adjusted torch-ID is transferred to the torch.
14.6
Special functions
Gas test, control panel test
Â
Press the mode switch on the top right 47 and the main
parameter switch on the bottom right 48 simultaneously.
The gas test is started for approx. 30 seconds. All LEDs and
the 7-segment display light up briefly simultaneously.
Â
If you press both switches again, the gas test ends.
Master reset
All welding and secondary parameters are re-
set to their factory settings (master reset func-
tion).
Â
Press the button Welding Process 30 top left and hold
down.
Â
Also briefly press the button main parameters 48 bottom
right.
9
All LEDs and 7-segment displays light up briefly.
9
ii
Summary of Contents for T 180 AC BasicPlus
Page 11: ...Vor der Inbetriebnahme 11 01 21 909 2669 9 02 ...
Page 35: ...Before commissioning 35 01 21 909 2669 9 02 ...
Page 59: ...Antes de la puesta en marcha 59 01 21 909 2669 9 02 ...
Page 83: ...Voor de inbedrijfstelling 83 01 21 909 2669 9 02 ...
Page 107: ...Перед вводом в эксплуатацию 107 01 21 909 2669 9 02 ...
Page 131: ...Przed uruchomieniem 131 01 21 909 2669 9 02 ...
Page 155: ...Antes de colocar em funcionamento 155 01 21 909 2669 9 02 ...
Page 179: ...Avant la mise en service 179 01 21 909 2669 9 02 ...
Page 203: ...Před uvedením do provozu 203 01 21 909 2669 9 02 ...
Page 227: ...Prima di cominciare 227 01 21 909 2669 9 02 ...