Starting up
- 40 -
01.21
909.2669.9-02
14.4
Powermaster parameters
All Powermaster torches of the i-LTG/i-LTW – serie have two
free programmable parameter spaces (PL3 and PL4).
Â
Select sub parameter PL3 or PL4.
9
The 7-segment display 38 shows alternating code PL3 or
PL4 and the code of the selected Powermaster parameter.
Â
Select the required Powermaster parameter with the turn-
ing knob 41.
Parameter
Range
Factory
setting
Code
Gas pre-flow time
0,1 - 10 sec
0,1
Start current IS
5 - 200 %
of main current
50
Start current time
0 - 20 sec.
0,1
Upslope
0 - 99 %
5
Second current I2
1 - 200 %
of main current
representation in
Amp.
50
Downslope
0 - 99 %
20
Final current IE
5 - 200 %
of main current
25
Final current time tE
0 - 20 sec.
0,2
Gas post-flow time
correction
20 - 500 %
100
Pulse frequency
0,2 - 2000 Hz
5
Pulse duty factor
1 - 99 %
Main current I1
50
AC-balance
1
10 - 90 %
positive welding
current
35
AC-frequency
1
30 - 200 Hz
60
Tab. 4:
Powermaster parameters
1)
14.5
User-specific menu
Â
Switch off the equipment at the main switch 9.
Â
Press the selection button on the left 30 and keep it de-
pressed.
Â
Switch on the equipment at the main switch 9
9
The user-specific menu is activated. The menu item and its
set value are shown alternating in the 7-segment display
38
Â
Press the selection button 30 or 47 to switch among the
menu items.
Â
Turn the control dial 41 to change the set value.
1)
Only for AC/DC
Menu
no.
Menu item
Setting
values
C00
Display and adjustment of the torch-ID. See „Ad-
justment of the torch-ID“ on page 41.
9...45
C01
Welding current limit for up/down torch. When
the welding current limit is switched to “On”, the
welding current on the up/down torch cannot
be set higher than pre-selected on the control
terminal.
On-Off
C02
Deactivation of the error message E05-00 (water
pump) and of the water cooling unit by Lorch-
Net.
If the deactivation is switched “on”, the error mes-
sage E05-00 (water pump) is no longer displayed.
Also the water cooling unit is not switched on by
LorchNet.
Practical, e.g. for the use of an automatic torch
without plug or a cooling unit without LorchNet.
On-Off
C03
Activation of the orbital welding mode.
On-Off
C04
ON: at short circuit the welding current don’t
increase the adjusted welding current shown in
the display (set value).
Off: at short circuit the welding current is in-
creased on minimum 60 A.
On-Off
C05
ON: by quick pressing of torch button 1 (start /
stop) the 2nd torch button is simulated.
(Second current on / off). Useful e.g. for torches
with one button only.
On-Off
C06
ON: the current decrease (downslope) will be - as
adjusted – conducted, also if the torch button is
released (4th tact).
Off: at earlier release of the torch button (4th
tact) the current decrease (downslope) is inter-
rupted.
On-Off
C07
On: PE conductor monitoring activated
Off: PE conductor monitoring deactivated
the PE conductor monitoring is an optional avail-
able feature
On-Off
C08
Off: Using a foot remote control, the minimum
current (independent from the adjusted welding
current) in the TIG mode / AC at
electrode-Ø 1,0...2,0 mm
= 10 Amps
electrode -Ø 2,4 mm
= 15 Amps
electrode -Ø 3,2 mm
= 20 Amps
On: the increased minimum current in the TIG-
mode / AC is deactivated
On-Off
C10
Welding current limit
0 = Off
I1
Min
...I1
Max
= On
0,
I1
Min
...
I1
Max
Tab. 5:
User-specific menu
Â
Switch the equipment off at the main switch 9 to transfer
the settings from the user-specific menu.
Summary of Contents for T 180 AC BasicPlus
Page 11: ...Vor der Inbetriebnahme 11 01 21 909 2669 9 02 ...
Page 35: ...Before commissioning 35 01 21 909 2669 9 02 ...
Page 59: ...Antes de la puesta en marcha 59 01 21 909 2669 9 02 ...
Page 83: ...Voor de inbedrijfstelling 83 01 21 909 2669 9 02 ...
Page 107: ...Перед вводом в эксплуатацию 107 01 21 909 2669 9 02 ...
Page 131: ...Przed uruchomieniem 131 01 21 909 2669 9 02 ...
Page 155: ...Antes de colocar em funcionamento 155 01 21 909 2669 9 02 ...
Page 179: ...Avant la mise en service 179 01 21 909 2669 9 02 ...
Page 203: ...Před uvedením do provozu 203 01 21 909 2669 9 02 ...
Page 227: ...Prima di cominciare 227 01 21 909 2669 9 02 ...