Step
Check
Yes
No
1
Check the media condition.
Load new, dry, recommended media.
Reprint the defective image.
Does the problem remain?
Go to step 2.
Problem
resolved
2
Check the media transfer route.
Is the media path free of contamination or debris?
Go to step 3.
Remove debris
or
contamination.
3
Check the four PC cartridges for proper installation.
Check the PC cartridge connections.
Are the PC cartridge connections free of excess
wear and contamination?
Go to step 4.
Correct and
clean
contaminated
pins, or replace
the appropriate
PC cartridge or
connector.
4
Check the 2nd transfer roller for contamination and
wear.
Is the 2nd transfer roller free of excess wear and
contamination?
Go to step 5.
Replace the 2nd
transfer roller.
Go to
“2nd
transfer roller
removal” on
page 4-28
.
5
Replace the transfer belt cleaner. Go to xxx.
Does the problem remain?
Go to step 6.
Problem
resolved
6
Check the developer HVPS PCBA for proper
connectivity. Disconnect and reconnect all appropriate
cables.
Replace the developer HVPS PCBA.
Go to
“Developer HVPS PCBA removal” on
page 4-75
.
Perform a print test.
Does the problem remain?
Go to step 7.
Problem
resolved
Leading edge
Trailing edge
Summary of Contents for X95 series
Page 26: ...xxvi Service Manual 7558 xxx Go Back Previous Next ...
Page 34: ...xxxiv Service Manual 7558 xxx Go Back Previous Next ...
Page 52: ...1 18 Service Manual 7558 xxx Go Back Previous Next ...
Page 464: ...3 112 Service Manual 7558 xxx Go Back Previous Next TTM theory of operations ...
Page 471: ...Diagnostic aids 3 119 7558 xxx Go Back Previous Next 3TM theory of operations ...
Page 477: ...Diagnostic aids 3 125 7558 xxx Go Back Previous Next 1TM theory of operations ...
Page 494: ...3 142 Service Manual 7558 xxx Go Back Previous Next ...
Page 506: ...4 12 Service Manual 7558 xxx Go Back Previous Next 6 Remove the operator panel top cover ...
Page 512: ...4 18 Service Manual 7558 xxx Go Back Previous Next 5 Remove the rear lower cover ...
Page 619: ...Repair information 4 125 7558 xxx Go Back Previous Next 4 Detach the media feed lift motor ...
Page 704: ...4 210 Service Manual 7558 xxx Go Back Previous Next 8 Remove the LED ...
Page 730: ...4 236 Service Manual 7558 xxx Go Back Previous Next 14 Remove the flatbed scanner assembly ...
Page 1038: ...6 12 Service Manual 7558 xxx Go Back Previous Next ...
Page 1076: ...7 38 Service Manual 7558 xxx Go Back Previous Next Assembly 37 TTM media feed 2 ...
Page 1112: ...7 74 Service Manual 7558 xxx Go Back Previous Next Assembly 71 Finisher punch 8 4 3 10 11 ...
Page 1158: ...7 120 Service Manual 7558 xxx Go Back Previous Next ...
Page 1168: ...I 10 Service Manual 7558 xxx Go Back Previous Next ...