2-264
Service Manual
7558-
xxx
Go Back
Previous
Next
4
Properly connect the cables to the RIP board. Restart
the device into Diagnostic mode.
Does the 900.xx error reoccur during startup?
Go to step 5.
Go to step 6.
5
Replace the RIP board, and restart the device.
Does this fix the problem?
Note:
If an error, different from the original 900.xx, is
displayed, consult the service check for that error.
Problem resolved
Go to step 31.
6
Print the following:
• Error log
• Menu settings page
• Network settings page
Does the 900.xx error reoccur while these pages
were printing?
Go to step 31.
Go to step 7.
7
Re-attach the communications cable. Restart the
printer to operating mode. Send the printer a print job.
Does the 900.xx error reoccur?
Note:
Before performing this step, write down this
information about the file being sent to the printer:
• Application used
• Operating system
• Driver type
• File type (PCL, PostScript, XPS, etc.)
Go to step 8.
Go to step 10.
8
Restart the printer to operating mode. Send a different
print job to the device.
Does the 900.xx error reoccur?
Go to step 9.
Go to step 10.
9
Upgrade the firmware. Contact your next level of
support for the correct firmware level to use.
Restart the printer to operating mode. Send the printer
a print job.
Does the 900.xx error reoccur?
Go to step 31.
Go to step 10.
10
Is the device a Multi-function printer?
Go to step 11.
Go to step 13.
11
Run a copy job.
Does the 900.xx error reoccur?
Go to step 31.
Go to step 12.
12
Run a scan to PC job.
Does the 900.xx error reoccur?
Go to step 31.
Go to step 13.
13
Is there optional memory installed?
Go to step 14.
Go to step16.
14
Reinstall the memory, and send a print job to the
device.
Does the 900.xx error reoccur?
Go to step 15.
Go to step 16.
Step
Action and questions
Yes
No
Summary of Contents for X95 series
Page 26: ...xxvi Service Manual 7558 xxx Go Back Previous Next ...
Page 34: ...xxxiv Service Manual 7558 xxx Go Back Previous Next ...
Page 52: ...1 18 Service Manual 7558 xxx Go Back Previous Next ...
Page 464: ...3 112 Service Manual 7558 xxx Go Back Previous Next TTM theory of operations ...
Page 471: ...Diagnostic aids 3 119 7558 xxx Go Back Previous Next 3TM theory of operations ...
Page 477: ...Diagnostic aids 3 125 7558 xxx Go Back Previous Next 1TM theory of operations ...
Page 494: ...3 142 Service Manual 7558 xxx Go Back Previous Next ...
Page 506: ...4 12 Service Manual 7558 xxx Go Back Previous Next 6 Remove the operator panel top cover ...
Page 512: ...4 18 Service Manual 7558 xxx Go Back Previous Next 5 Remove the rear lower cover ...
Page 619: ...Repair information 4 125 7558 xxx Go Back Previous Next 4 Detach the media feed lift motor ...
Page 704: ...4 210 Service Manual 7558 xxx Go Back Previous Next 8 Remove the LED ...
Page 730: ...4 236 Service Manual 7558 xxx Go Back Previous Next 14 Remove the flatbed scanner assembly ...
Page 1038: ...6 12 Service Manual 7558 xxx Go Back Previous Next ...
Page 1076: ...7 38 Service Manual 7558 xxx Go Back Previous Next Assembly 37 TTM media feed 2 ...
Page 1112: ...7 74 Service Manual 7558 xxx Go Back Previous Next Assembly 71 Finisher punch 8 4 3 10 11 ...
Page 1158: ...7 120 Service Manual 7558 xxx Go Back Previous Next ...
Page 1168: ...I 10 Service Manual 7558 xxx Go Back Previous Next ...