Diagnostic information
2-103
7558-
xxx
Go Back
Previous
Next
5
Check the registration drive
motor for proper connection.
Is the above component
properly connected?
Replace the registration drive
motor.
Go to
“Registration drive motor
removal” on page 4-150
.
Replace the connection.
6
Check the 2nd transfer roller
contact retract motor assembly
for proper operation.
When performing
motor tests, ensure
that all cover and
door interlock
switches are
overridden.
1. Enter the Diagnostics Menu.
2. Touch
MOTOR TESTS
.
3. Touch
PRINTER MOTOR
TESTS
.
4. Touch
2nd Transfer Rollers
Retract Motor (contacted)
.
5. Touch
2nd Transfer Rollers
Retract Motor (retracted)
.
Does the above component
operate properly?
Go to step 8.
Go to step 7.
7
Check the 2nd transfer roller
contact retract motor assembly
for proper connection.
Is the above component
properly connected?
Replace the 2nd transfer roller
contact retract motor assembly.
Go to
“2nd Transfer Roller
Contact Retract Motor
assembly removal” on page
.
Replace the connection.
8
Check the media transport/MPF
drive motor assembly for proper
operation.
When performing
motor tests, ensure
that all cover and
door interlock
switches are
overridden.
1. Enter the Diagnostics Menu.
2. Touch
MOTOR TESTS
.
3. Touch
PRINTER MOTOR
TESTS
.
4. Touch
MPF feed/lift motor
(pick)
.
5. Touch
MPF feed/lift motor
(feed) Test
.
Does the above component
operate properly?
Go to step 10.
Go to step 9.
9
Check the media transport/MPF
drive motor assembly for proper
connection.
Is the above component
properly connected?
Replace the media transport/MPF
drive motor assembly.
Go to
“Media transport/MPF
drive motor removal” on
page 4-127
.
Replace the connection.
Step
Action and questions
Yes
No
Summary of Contents for X95 series
Page 26: ...xxvi Service Manual 7558 xxx Go Back Previous Next ...
Page 34: ...xxxiv Service Manual 7558 xxx Go Back Previous Next ...
Page 52: ...1 18 Service Manual 7558 xxx Go Back Previous Next ...
Page 464: ...3 112 Service Manual 7558 xxx Go Back Previous Next TTM theory of operations ...
Page 471: ...Diagnostic aids 3 119 7558 xxx Go Back Previous Next 3TM theory of operations ...
Page 477: ...Diagnostic aids 3 125 7558 xxx Go Back Previous Next 1TM theory of operations ...
Page 494: ...3 142 Service Manual 7558 xxx Go Back Previous Next ...
Page 506: ...4 12 Service Manual 7558 xxx Go Back Previous Next 6 Remove the operator panel top cover ...
Page 512: ...4 18 Service Manual 7558 xxx Go Back Previous Next 5 Remove the rear lower cover ...
Page 619: ...Repair information 4 125 7558 xxx Go Back Previous Next 4 Detach the media feed lift motor ...
Page 704: ...4 210 Service Manual 7558 xxx Go Back Previous Next 8 Remove the LED ...
Page 730: ...4 236 Service Manual 7558 xxx Go Back Previous Next 14 Remove the flatbed scanner assembly ...
Page 1038: ...6 12 Service Manual 7558 xxx Go Back Previous Next ...
Page 1076: ...7 38 Service Manual 7558 xxx Go Back Previous Next Assembly 37 TTM media feed 2 ...
Page 1112: ...7 74 Service Manual 7558 xxx Go Back Previous Next Assembly 71 Finisher punch 8 4 3 10 11 ...
Page 1158: ...7 120 Service Manual 7558 xxx Go Back Previous Next ...
Page 1168: ...I 10 Service Manual 7558 xxx Go Back Previous Next ...