Diagnostic information
2-289
7558-
xxx
Go Back
Previous
Next
3
Check the four PC cartridges for spots or other damage
on the drum surfaces.
Are the PC cartridges free of excess wear and
contamination?
Go to step 4.
Replace the
appropriate PC
cartridge or
connector.
4
Print the print quality page suite.
Do the spots repeat for a given color?
Replace the
appropriate
printhead. Go to
“LED printhead
removal” on
page 4-105
.
Go to step 5.
5
Check the heat belt and pressure roll in the fuser
assembly for scratches or defects.
CAUTION
: The fuser assembly might be hot.
Allow the fuser assembly to cool.
Remove the fuser assembly.
Is there contamination or cracks on the heat belt
and/or pressure roll?
Replace the
fuser assembly.
Go to
“Fuser
assembly
removal” on
page 4-87
.
Go to step 6.
6
Check the 2nd transfer roller for contamination and wear.
Is the 2nd transfer roller free of excess wear and
contamination?
Go to step 7.
Replace the 2nd
transfer roller.
Go to
“2nd
transfer roller
removal” on
page 4-28
.
7
Replace the transfer belt assembly. Go to
“Transfer belt
assembly removal” on page 4-178
.
Does the problem remain?
Go to step 8.
Problem
resolved
8
Check the LED printhead assembly.
Replace the LED printhead assembly.
Go to
“LED printhead removal” on page 4-105
.
Does the problem remain?
Go to step 9.
Problem
resolved
9
Check the upper printer engine PCBA for proper
connectivity. Disconnect and reconnect all appropriate
cables.
Replace the upper printer engine PCBA.
Go to
“Upper printer engine PCBA removal” on
page 4-189
.
Perform a print test.
Does the problem remain?
Replace the RIP
card PCBA.
Go to
“RIP
PCBA removal”
on page 4-153
.
Problem
resolved
Step
Check
Yes
No
Summary of Contents for X95 series
Page 26: ...xxvi Service Manual 7558 xxx Go Back Previous Next ...
Page 34: ...xxxiv Service Manual 7558 xxx Go Back Previous Next ...
Page 52: ...1 18 Service Manual 7558 xxx Go Back Previous Next ...
Page 464: ...3 112 Service Manual 7558 xxx Go Back Previous Next TTM theory of operations ...
Page 471: ...Diagnostic aids 3 119 7558 xxx Go Back Previous Next 3TM theory of operations ...
Page 477: ...Diagnostic aids 3 125 7558 xxx Go Back Previous Next 1TM theory of operations ...
Page 494: ...3 142 Service Manual 7558 xxx Go Back Previous Next ...
Page 506: ...4 12 Service Manual 7558 xxx Go Back Previous Next 6 Remove the operator panel top cover ...
Page 512: ...4 18 Service Manual 7558 xxx Go Back Previous Next 5 Remove the rear lower cover ...
Page 619: ...Repair information 4 125 7558 xxx Go Back Previous Next 4 Detach the media feed lift motor ...
Page 704: ...4 210 Service Manual 7558 xxx Go Back Previous Next 8 Remove the LED ...
Page 730: ...4 236 Service Manual 7558 xxx Go Back Previous Next 14 Remove the flatbed scanner assembly ...
Page 1038: ...6 12 Service Manual 7558 xxx Go Back Previous Next ...
Page 1076: ...7 38 Service Manual 7558 xxx Go Back Previous Next Assembly 37 TTM media feed 2 ...
Page 1112: ...7 74 Service Manual 7558 xxx Go Back Previous Next Assembly 71 Finisher punch 8 4 3 10 11 ...
Page 1158: ...7 120 Service Manual 7558 xxx Go Back Previous Next ...
Page 1168: ...I 10 Service Manual 7558 xxx Go Back Previous Next ...