2-132
Service Manual
7558-
xxx
Go Back
Previous
Next
245.06 Sensor (tray 5 feed out) lag jam
6
Check the HCF feed lift motor for
proper connection.
Is the above component
properly connected?
Replace the HCF feed lift motor.
Go to
“HCF feed lift motor
removal” on page 4-433
.
Replace the connections.
7
Check the HCF transport motor
for proper operation.
When performing
motor tests, ensure
that all cover and
door interlock
switches are
overridden.
1. Enter the Diagnostics Menu.
2. Touch
MOTOR TESTS
.
3. Touch
PRINTER MOTOR
TESTS
.
4. Touch
HCF transport motor
.
Does the above component
operate properly?
Go to step 9.
Go to step 8.
8
Check the HCF transport motor
for proper connection.
Is the above component
properly connected?
Replace the HCF transport
motor. Go to
“HCF transport
motor removal” on page 4-452
.
Replace the connections.
9
Check the the HCF controller
card PCBA for proper connection.
Is the above component
properly connected?
Replace the HCF controller card
PCBA. Go to
“HCF controller
card PCBA removal” on
page 4-432
.
Go to step 10.
Replace the connections.
10
POR the machine, and perform a
print test. Go to
“PRINT TESTS”
on page 3-26
.
Does the error continue?
Replace the upper printer engine
PCBA.
Go to
“Upper printer engine
PCBA removal” on page 4-189
.
Problem resolved
Step
Action and questions
Yes
No
1
Check the media path.
Is the media path free of any
media fragments?
Go to step 2.
Remove any media or media
fragments.
2
Check the feed rollers for wear.
Is the above component free of
excess wear and damage?
Go to step 3.
Replace the feed roll assembly.
Go to
“HCF feed roll assembly
removal” on page 4-434
.
Step
Action and questions
Yes
No
Summary of Contents for X95 series
Page 26: ...xxvi Service Manual 7558 xxx Go Back Previous Next ...
Page 34: ...xxxiv Service Manual 7558 xxx Go Back Previous Next ...
Page 52: ...1 18 Service Manual 7558 xxx Go Back Previous Next ...
Page 464: ...3 112 Service Manual 7558 xxx Go Back Previous Next TTM theory of operations ...
Page 471: ...Diagnostic aids 3 119 7558 xxx Go Back Previous Next 3TM theory of operations ...
Page 477: ...Diagnostic aids 3 125 7558 xxx Go Back Previous Next 1TM theory of operations ...
Page 494: ...3 142 Service Manual 7558 xxx Go Back Previous Next ...
Page 506: ...4 12 Service Manual 7558 xxx Go Back Previous Next 6 Remove the operator panel top cover ...
Page 512: ...4 18 Service Manual 7558 xxx Go Back Previous Next 5 Remove the rear lower cover ...
Page 619: ...Repair information 4 125 7558 xxx Go Back Previous Next 4 Detach the media feed lift motor ...
Page 704: ...4 210 Service Manual 7558 xxx Go Back Previous Next 8 Remove the LED ...
Page 730: ...4 236 Service Manual 7558 xxx Go Back Previous Next 14 Remove the flatbed scanner assembly ...
Page 1038: ...6 12 Service Manual 7558 xxx Go Back Previous Next ...
Page 1076: ...7 38 Service Manual 7558 xxx Go Back Previous Next Assembly 37 TTM media feed 2 ...
Page 1112: ...7 74 Service Manual 7558 xxx Go Back Previous Next Assembly 71 Finisher punch 8 4 3 10 11 ...
Page 1158: ...7 120 Service Manual 7558 xxx Go Back Previous Next ...
Page 1168: ...I 10 Service Manual 7558 xxx Go Back Previous Next ...