Diagnostic aids
3-27
7558-
xxx
Go Back
Previous
Next
PRINTER SETUP
Configuration ID
This setting enables a user to change both Configuration ID 1 and Configuration ID 2.
Mono and Color Page Count
The values of these settings enable a user to gauge the amount and type of usage on a device. The Mono Page
Count setting’s value will equal the value of the Picked Sides meter. The Color Page Count setting’s value will
equal the value of the Total Color sub-meter within the Imaged Printed Sides meter.
Parallel Strobe Adjustment (all parallel ports)
This setting enables the user to adjust the amount of time the strobe is sampled in order to determine if valid
data is available on the parallel port. Each time this value is incremented by 1, the strobe is sampled 50
nanoseconds longer. Each time this value is decreased by 1, the strobe is sampled 50 nanoseconds less. When
the value of this setting is 0, the factory default value is used to determine the length of time the strobe is
sampled.
To change this setting:
1.
From the Diagnostics Menu, navigate to
PRINTER SETUP
.
2.
Select
Par 1 Strobe Adj
.
3.
Touch
or
to change the value.
4.
Touch
Submit
to save the setting, or touch
Back
to return to the Diagnostics Menu without saving any
changes.
Permanent Page Count
The value of this setting indicates the total number of pages that have been printed by the device.
Reset Color Calibration
This setting enables the device to adjust the alignment of its color planes using pre-programmed default values.
Using this setting to adjust color plane linearization may not provide a calibration as effective as using Automatic
Color Adjust Calibration. While this text executes, the panel posts
Resetting
.
Serial Number
This setting records the device’s 13-character (last character is a null value) serial number that was assigned by
manufacturing.
U.S. / Non-U.S. Defaults
The value of this setting determines whether the device uses the U.S. or Non-U.S. factory default value.
To change this setting:
1.
From the Diagnostics Menu, navigate to
PRINTER SETUP
.
2.
Select
Defaults
.
3.
Touch
or
to change the value.
4.
Touch
Submit
to save the setting, or touch
Back
to return to the Diagnostics Menu without saving any
changes.
Summary of Contents for X95 series
Page 26: ...xxvi Service Manual 7558 xxx Go Back Previous Next ...
Page 34: ...xxxiv Service Manual 7558 xxx Go Back Previous Next ...
Page 52: ...1 18 Service Manual 7558 xxx Go Back Previous Next ...
Page 464: ...3 112 Service Manual 7558 xxx Go Back Previous Next TTM theory of operations ...
Page 471: ...Diagnostic aids 3 119 7558 xxx Go Back Previous Next 3TM theory of operations ...
Page 477: ...Diagnostic aids 3 125 7558 xxx Go Back Previous Next 1TM theory of operations ...
Page 494: ...3 142 Service Manual 7558 xxx Go Back Previous Next ...
Page 506: ...4 12 Service Manual 7558 xxx Go Back Previous Next 6 Remove the operator panel top cover ...
Page 512: ...4 18 Service Manual 7558 xxx Go Back Previous Next 5 Remove the rear lower cover ...
Page 619: ...Repair information 4 125 7558 xxx Go Back Previous Next 4 Detach the media feed lift motor ...
Page 704: ...4 210 Service Manual 7558 xxx Go Back Previous Next 8 Remove the LED ...
Page 730: ...4 236 Service Manual 7558 xxx Go Back Previous Next 14 Remove the flatbed scanner assembly ...
Page 1038: ...6 12 Service Manual 7558 xxx Go Back Previous Next ...
Page 1076: ...7 38 Service Manual 7558 xxx Go Back Previous Next Assembly 37 TTM media feed 2 ...
Page 1112: ...7 74 Service Manual 7558 xxx Go Back Previous Next Assembly 71 Finisher punch 8 4 3 10 11 ...
Page 1158: ...7 120 Service Manual 7558 xxx Go Back Previous Next ...
Page 1168: ...I 10 Service Manual 7558 xxx Go Back Previous Next ...