Diagnostic information
2-259
7558-
xxx
Go Back
Previous
Next
846.10 Sensor (ADF scan width [x]) failure
3
Perform a POR.
Does the error remain when the
power is turned off/on?
Replace the scanner controller
card assembly.
Go to
“Scanner controller
PCBA removal” on page 4-241
.
Problem solved.
Step
Action and questions
Yes
No
1
Check the sensor (ADF scan
width 1) for operation.
Perform the sensor (ADF scan
width 1) test.
Open the ADF left cover
assembly.
1. Enter the Diagnostics Menu.
2. Touch
SENSOR TESTS
.
3. Touch
ADF/SCANNER
TESTS
.
4. Touch
Sensor(ADF scan
width 1)
.
Operate the actuator of the
sensor (ADF scan width 1).
Does the display on the
operator panel change every
time the sensing area of the
above sensor is blocked?
Go to step 3.
Go to step 2.
2
Check the sensor (ADF scan
width 1) for connection.
Is the above sensor connected
properly?
Replace the sensor (ADF scan
width 1).
Go to
“Sensor (ADF scan width
1) removal” on page 4-254
.
Replace the connection.
3
Check the sensor (ADF scan
width 2) for operation.
Perform the sensor (ADF scan
width 2) test.
Open the ADF left cover
assembly.
1. Enter the Diagnostics Menu.
2. Touch
SENSOR TESTS
.
3. Touch
ADF/SCANNER
TESTS
.
4. Touch
Sensor(ADF scan
width 2)
.
Operate the actuator of the
sensor (ADF scan width 2).
Does the display on the
operator panel change every
time the sensing area of the
above sensor is blocked?
Go to step 5.
Go to step 4.
Step
Action and questions
Yes
No
Summary of Contents for X95 series
Page 26: ...xxvi Service Manual 7558 xxx Go Back Previous Next ...
Page 34: ...xxxiv Service Manual 7558 xxx Go Back Previous Next ...
Page 52: ...1 18 Service Manual 7558 xxx Go Back Previous Next ...
Page 464: ...3 112 Service Manual 7558 xxx Go Back Previous Next TTM theory of operations ...
Page 471: ...Diagnostic aids 3 119 7558 xxx Go Back Previous Next 3TM theory of operations ...
Page 477: ...Diagnostic aids 3 125 7558 xxx Go Back Previous Next 1TM theory of operations ...
Page 494: ...3 142 Service Manual 7558 xxx Go Back Previous Next ...
Page 506: ...4 12 Service Manual 7558 xxx Go Back Previous Next 6 Remove the operator panel top cover ...
Page 512: ...4 18 Service Manual 7558 xxx Go Back Previous Next 5 Remove the rear lower cover ...
Page 619: ...Repair information 4 125 7558 xxx Go Back Previous Next 4 Detach the media feed lift motor ...
Page 704: ...4 210 Service Manual 7558 xxx Go Back Previous Next 8 Remove the LED ...
Page 730: ...4 236 Service Manual 7558 xxx Go Back Previous Next 14 Remove the flatbed scanner assembly ...
Page 1038: ...6 12 Service Manual 7558 xxx Go Back Previous Next ...
Page 1076: ...7 38 Service Manual 7558 xxx Go Back Previous Next Assembly 37 TTM media feed 2 ...
Page 1112: ...7 74 Service Manual 7558 xxx Go Back Previous Next Assembly 71 Finisher punch 8 4 3 10 11 ...
Page 1158: ...7 120 Service Manual 7558 xxx Go Back Previous Next ...
Page 1168: ...I 10 Service Manual 7558 xxx Go Back Previous Next ...