806f050d-0411ffff : Array [ComputerSystemElementName] is in critical condition. (Drive 17)
This message is for the use case when an implementation has detected that an Array is Critical.
May also be shown as 806f050d0411ffff or 0x806f050d0411ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix:
PLAT
ID:
0174
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3.
Replace the SAS cable.
4. Check backplane cable connection.
5.
Replace the RAID adapter.
6. Replace the hard disk drive that is indicated by a lit status LED.
•
806f050d-0412ffff : Array [ComputerSystemElementName] is in critical condition. (Drive 18)
This message is for the use case when an implementation has detected that an Array is Critical.
May also be shown as 806f050d0412ffff or 0x806f050d0412ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
Appendix A. Integrated management module II (IMM2) error messages
721
Summary of Contents for x3650 M5
Page 1: ...Lenovo System x3650 M5 Installation and Service Guide Machine Type 8871 ...
Page 47: ...Figure 35 System board switches jumpers and buttons Chapter 1 The System x3650 M5 server 35 ...
Page 60: ...48 Lenovo System x3650 M5 Installation and Service Guide ...
Page 80: ...68 Lenovo System x3650 M5 Installation and Service Guide ...
Page 124: ...112 Lenovo System x3650 M5 Installation and Service Guide ...
Page 146: ...134 Lenovo System x3650 M5 Installation and Service Guide ...
Page 1322: ...1310 Lenovo System x3650 M5 Installation and Service Guide ...
Page 1330: ...Taiwan BSMI RoHS declaration 1318 Lenovo System x3650 M5 Installation and Service Guide ...
Page 1339: ......
Page 1340: ......